User name apar
Log entry time 12:58:45 on April 17, 2003
Entry number 97770
keyword=Start_Parity_Run_2660__CODA_Config=Beamline
Beginning-of-Parity-run EPICS data for Run Number 2660 at Thu Apr 17 12:58:37 EDT 2003
CODA Configuration: Beamline
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 44.8063
Wien BDL : 1028.6
Wien field : 29.811
Laser attenuation Hall A : 300
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 5.53728
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.22359
Gun2: PC (PITA) NEG : 7.457
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
IA Feedback Control Hall A : disabled
IA Charge Asymmetry Hall A : -0.34
IA Timestamp Hall A : 1045195497
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -0.5
LUMI 2 HV - Ch 11 : -0.3
LUMI 3 HV - Ch 9 : 0.3
Left Arm Q1 momentum : 0
Left Arm Q2 power supply current : 0.136862
Left Arm Q2 momentum : 0.000317841
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 0.139254
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.215136
Left Arm Q3 power supply current : 1.92477
Left Arm Q3 momentum : 0.00483467
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.499665
Right Arm Q1 gauss meter : -0.009481
Right Arm Q2 power supply current : 0.23096
Right Arm Q2 momentum : 0.000536657
Right Arm Q2 gauss meter : 0.0001601
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1.83333
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.326806
Right Arm Q3 power supply current : -0.000966717
Right Arm Q3 momentum : -2.42949e-06
Right Arm Q3 gauss meter : -0.0002105
Right Arm Q3 power supply polarity : enabled
Right Arm Top VDC voltage : -0.00634766
Right Arm Bottom VDC voltage : -0.0151367
Average current of the two cavities : 0.0168339
Current on Unser monitor : -15.1825
Current on Upstream bcm : 0.0185265
Current on Downstream bcm : 0.0151412
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143715
Tiefenbach Hall A energy : 5008.97
Tiefenbach Hall C energy : 2238.42
Delta(E)/E width (MV_AI_DXWID) : 3.42142
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 2242.19
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Arm Collimator : 0.0651367
HacL_HPE1313A:0_Ch58 : -0.15332
HacL_HPE1313A:0_Ch55 : 22.5586
HacL_HPE1313A:0_Ch54 : -0.0703125
Right Arm Arm Collimator : 9.76563e-05
Right LVDT HPM : 3215
Right LVDT VPM : 3866
HacR_HPE1313A:0_Ch58 : -0.529785
HacR_HPE1313A:0_Ch55 : 21.875
HacR_HPE1313A:0_Ch54 : -0.842285
HacR_alignROLL : 0
HacR_alignPITCH : 0
HacR_alignHPT : 0
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Target OTR x-position : 0.236669
Target OTR y-position : -3.15004
Target OTR x-width : 3.16157
Target OTR y-width : 2.27851
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : -2.06488
Arc OTR y-position : -0.139931
Arc OTR x-width : 2.96554
Arc OTR y-width : 3.03807
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out