Main INDEX
Monthly INDEX
PREV
NEXT
User name apar
Log entry time 14:20:24 on April 17, 2003
Entry number 97784
keyword=Start_Parity_Run_2667__CODA_Config=GDH_Minimal
Beginning-of-Parity-run EPICS data for Run Number 2667 at Thu Apr 17 14:20:15 EDT 2003
CODA Configuration: GDH_Minimal
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 44.8063
Wien BDL : 1028.6
Wien field : 29.811
Laser attenuation Hall A : 300
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 5.53728
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.22359
Gun2: PC (PITA) NEG : 7.457
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
IA Feedback Control Hall A : disabled
IA Charge Asymmetry Hall A : -0.34
IA Timestamp Hall A : 1045195497
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -0.5
LUMI 2 HV - Ch 11 : -0.3
LUMI 3 HV - Ch 9 : 0.3
Left Arm Q1 momentum : 0.499969
Left Arm Q2 power supply current : 215.301
Left Arm Q2 momentum : 0.500004
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 166.358
Left Arm D1 momentum : 0.498904
Left Arm D1 NMR : 0.184835
Left Arm Q3 power supply current : 199.195
Left Arm Q3 momentum : 0.500342
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.499949
Right Arm Q1 gauss meter : -0.009466
Right Arm Q2 power supply current : 215.26
Right Arm Q2 momentum : 0.500177
Right Arm Q2 gauss meter : 0.1125
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 172.686
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.410541
Right Arm Q3 power supply current : 0.140648
Right Arm Q3 momentum : 0.000353468
Right Arm Q3 gauss meter : -0.0002056
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : -0.00537109
Right Arm Bottom VDC voltage : -0.015625
Average current of the two cavities : 0.0169237
Current on Unser monitor : -14.1908
Current on Upstream bcm : 0.0185942
Current on Downstream bcm : 0.0154211
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143715
Tiefenbach Hall A energy : 5008.97
Tiefenbach Hall C energy : 2238.39
Delta(E)/E width (MV_AI_DXWID) : 3.47695
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 2242.19
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Arm Collimator : 0.0650879
HacL_HPE1313A:0_Ch58 : -0.15332
HacL_HPE1313A:0_Ch55 : 22.5586
HacL_HPE1313A:0_Ch54 : -0.0727539
Right Arm Arm Collimator : 9.76563e-05
Right LVDT HPM : 3216
Right LVDT VPM : 3867
HacR_HPE1313A:0_Ch58 : -0.529785
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.842773
HacR_alignROLL : 0
HacR_alignPITCH : 0
HacR_alignHPT : 0
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Target OTR x-position : 0.426059
Target OTR y-position : -2.08648
Target OTR x-width : 2.8538
Target OTR y-width : 2.6551
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : -2.06476
Arc OTR y-position : -0.140168
Arc OTR x-width : 2.96546
Arc OTR y-width : 3.03795
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out