Log entry time 16:40:32 on April 17, 2003
Entry number 97821
keyword=Start_Parity_Run_2683__CODA_Config=Beamline
Beginning-of-Parity-run EPICS data for Run Number 2683 at Thu Apr 17 16:40:26 EDT 2003
CODA Configuration: Beamline
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 44.8063
Wien BDL : 1028.6
Wien field : 29.811
Laser attenuation Hall A : 500
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 5.53728
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.22359
Gun2: PC (PITA) NEG : 7.457
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : disabled
IA Charge Asymmetry Hall A : -30.76
IA Timestamp Hall A : 1050610759
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -0.5
LUMI 2 HV - Ch 11 : -0.3
LUMI 3 HV - Ch 9 : 0.3
Left Arm Q1 momentum : 0.50004
Left Arm Q2 power supply current : 215.297
Left Arm Q2 momentum : 0.499992
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 166.352
Left Arm D1 momentum : 0.498904
Left Arm D1 NMR : 0.184835
Left Arm Q3 power supply current : 199.061
Left Arm Q3 momentum : 0.500003
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.499949
Right Arm Q1 gauss meter : -0.009436
Right Arm Q2 power supply current : 0.136281
Right Arm Q2 momentum : 0.000316662
Right Arm Q2 gauss meter : 0.0001951
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 172.688
Right Arm D1 momentum : 0.482569
Right Arm D1 NMR : 0.179075
Right Arm Q3 power supply current : 0.144018
Right Arm Q3 momentum : 0.000361938
Right Arm Q3 gauss meter : -0.0002111
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : -0.00537109
Right Arm Bottom VDC voltage : -0.0151367
Average current of the two cavities : 0.0165492
Current on Unser monitor : -15.6322
Current on Upstream bcm : 0.0181549
Current on Downstream bcm : 0.0149436
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 39.2718
Tiefenbach Hall A energy : 5008.97
Tiefenbach Hall C energy : 4413.91
Delta(E)/E width (MV_AI_DXWID) : 2.77352
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 4424.84
MBSY1c magnet current (amp) : 209.525
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Arm Collimator : 0.064209
HacL_HPE1313A:0_Ch58 : -0.152832
HacL_HPE1313A:0_Ch55 : 22.6074
HacL_HPE1313A:0_Ch54 : -0.0727539
Right Arm Arm Collimator : -0.000195313
Right LVDT HPM : 3215
Right LVDT VPM : 3865
HacR_HPE1313A:0_Ch58 : -0.528809
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.843262
HacR_alignROLL : 0
HacR_alignPITCH : 0
HacR_alignHPT : 0
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Target OTR x-position : -0.852401
Target OTR y-position : -2.32581
Target OTR x-width : 2.0705
Target OTR y-width : 2.35994
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : -2.06461
Arc OTR y-position : -0.139744
Arc OTR x-width : 2.96554
Arc OTR y-width : 3.03817
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out