User name apar
Log entry time 10:06:57 on April 21, 2003
Entry number 97908
keyword=Start_Parity_Run_2694__CODA_Config=Injector
Beginning-of-Parity-run EPICS data for Run Number 2694 at Mon Apr 21 10:06:51 EDT 2003
CODA Configuration: Injector
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 44.8063
Wien BDL : 1028.6
Wien field : 29.811
Laser attenuation Hall A : 240
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 5.53728
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.22359
Gun2: PC (PITA) NEG : 7.457
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
IA Feedback Control Hall A : disabled
IA Charge Asymmetry Hall A : -0.9
IA Timestamp Hall A : 1050613318
IA Slope Hall A : 10000
LUMI 1 HV - Ch 10 : -0.5
LUMI 2 HV - Ch 11 : -0.3
LUMI 3 HV - Ch 6 : -0.4
LUMI 4 HV - Ch 7 : -0.2
Left Arm Q1 momentum : 0.499969
Left Arm Q2 power supply current : 215.242
Left Arm Q2 momentum : 0.499865
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 166.726
Left Arm D1 momentum : 0.499992
Left Arm D1 NMR : 0.185237
Left Arm Q3 power supply current : 199.1
Left Arm Q3 momentum : 0.500101
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.500111
Right Arm Q1 gauss meter : -0.007281
Right Arm Q2 power supply current : 215.242
Right Arm Q2 momentum : 0.499981
Right Arm Q2 gauss meter : 0.11251
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 172.42
Right Arm D1 momentum : 0.499997
Right Arm D1 NMR : 0.185543
Right Arm Q3 power supply current : 227.977
Right Arm Q3 momentum : 0.500256
Right Arm Q3 gauss meter : 0.10149
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.9873
Right Arm Bottom VDC voltage : 3.99463
Average current of the two cavities : 0.0167342
Current on Unser monitor : -14.197
Current on Upstream bcm : 0.0186008
Current on Downstream bcm : 0.0148676
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143715
Tiefenbach Hall A energy : 1148.7
Tiefenbach Hall C energy : 4413.63
Delta(E)/E width (MV_AI_DXWID) : 2.93342
MBSY1c Hall A Beam energy : 1150.19
MBSY3c Hall C Beam energy : 4426.83
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 287032
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Arm Collimator : 0.0645508
HacL_HPE1313A:0_Ch58 : -0.146484
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : -0.0888672
Right Arm Arm Collimator : 0
Right LVDT HPM : 3218
Right LVDT VPM : 3869
HacR_HPE1313A:0_Ch58 : -0.558105
HacR_HPE1313A:0_Ch55 : 22.168
HacR_HPE1313A:0_Ch54 : -0.917969
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 18
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 17.9999
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Target OTR x-position : -1.30076
Target OTR y-position : -1.2799
Target OTR x-width : 2.13485
Target OTR y-width : 1.6304
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : -2.05806
Arc OTR y-position : -0.150663
Arc OTR x-width : 2.96457
Arc OTR y-width : 3.03206
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out