NEXT
User name a-onl
Log entry time 17:16:37 on April 22, 2003
Entry number 98078
keyword=End_of_Run_1195
****************************
Run Number: 1195
End of Run Comment:
Run_type=optics,beam_energy=1.148,beam_halfwaveplate=in,beam_raster=off,comment_text=raster check, dial raster=7.1*7.1 amps,daq_mode=both HRS daq,kin_name=,leftarm_p=500,leftarm_theta=18,rightarm_p=500,rightarm_theta=9,target_halfwaveplate=out,target_name=Proteus,target_polarization=0,target_type=carbon
PRESCALE FACTORS:ps1=10 ps2=100 ps3=9999 ps4=9999 ps5=65535 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 585976 [+]: 287764 [-]: 287673
TIME [0]: 2.532 mins [+]: 1.247 mins [-]: 1.247 mins
LIVE [0]: 99.56% [+]: 100.05% [-]: 99.95%
TRIGGER RATES: PRES/REAL
T1[0] :3843.0/38430.2 Hz T2[0] : 2.0/196.4 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :3841.6/38416.4 Hz T2[+] : 1.9/193.8 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :3844.8/38447.9 Hz T2[-] : 2.0/199.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 583736/5837368 T2[0] : 298/29825 T8[0] : 2/155541
T1[+] : 287466/2874668 T2[+] : 145/14504 T8[+] : 1/76625
T1[-] : 287665/2876650 T2[-] : 148/14892 T8[-] : 1/76615
AVERAGE CURRENT
BCM x1 : 0.9505 uA BCM x3 : 0.9693 uA BCM x10: 0.9337 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -355.3 ppm BCM u3 : -534.7 ppm BCM u10: -473.3 ppm
BCM d1 : -409.8 ppm BCM d3 : -272.3 ppm BCM d10: -473.9 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.0001464 BCM u3 [0]:0.0001441 BCM u10[0]:0.000143
BCM u1 [+]:7.19E-05 BCM u3 [+]:7.093E-05 BCM u10[+]:7.041E-05
BCM u1 [-]:7.194E-05 BCM u3 [-]:7.099E-05 BCM u10[-]:7.046E-05
BCM d1 [0]:0.0001423 BCM d3 [0]:0.0001504 BCM d10[0]:0.0001407
BCM d1 [+]:7.011E-05 BCM d3 [+]:7.617E-05 BCM d10[+]:6.927E-05
BCM d1 [-]:7.015E-05 BCM d3 [-]:7.62E-05 BCM d10[-]:6.933E-05
****************************
End-of-run EPICS data for Run Number 1195 at Tue Apr 22 17:16:05 EDT 2003
Left Arm D1 momentum : 1.06701
Left Arm arm angle : 18.0002
Right Arm D1 momentum : 1.14731
Right Arm arm angle : 12.5016
Tiefenbach Hall A energy : 1148.79
Left Arm arm mispointing (HPT) :
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : 1.5625
Left Arm Bottom VDC Current : 0.537109
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Right septum set current : 92.16
Right septum current readback : 220.5
Left Arm Q1 power supply current :
Left Arm Q1 momentum : 1.06695
Left Arm Q1 gauss meter :
Left Arm Q1 power supply polarity :
Left Arm Q2 power supply current : 459.458
Left Arm Q2 momentum : 1.06702
Left Arm Q2 gauss meter :
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 356.57
Left Arm D1 momentum : 1.06701
Left Arm D1 NMR : 0.395023
Left Arm Q3 power supply current : 424.714
Left Arm Q3 momentum : 1.0668
Left Arm Q3 gauss meter :
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current :
Right Arm Q1 momentum : 1.1473
Right Arm Q1 gauss meter : -0.017194
Right Arm Q1 power supply polarity :
Right Arm Q2 power supply current : 497.882
Right Arm Q2 momentum : 1.14733
Right Arm Q2 gauss meter : 0.2617
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 393.851
Right Arm D1 momentum : 1.14731
Right Arm D1 NMR : 0.425753
Right Arm Q3 power supply current : 537.35
Right Arm Q3 momentum : 1.14747
Right Arm Q3 gauss meter : 0.2409
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 1.15595
Current on Unser monitor : -13.6905
Current on Upstream bcm : 1.17013
Current on Downstream bcm : 1.14176
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 42.2994
MBSY1c Hall A Beam energy : 1150.19
MBSY1c magnet current (amp) : 47.6444
MBSY1c Bdl : 287032
MBSY3c Hall C Beam energy : 4426.83
Tiefenbach Hall A energy : 1148.79
Tiefenbach Hall C energy : 4413.54
Delta(E)/E width (MV_AI_DXWID) : 2.20321
IPM1C12.XPOS : 0.831243
IPM1H04A.XPOS : 0.440148
IPM1H04A.YPOS : -0.831855
IPM1H04B.XPOS : 0.22665
IPM1H04B.YPOS : -0.894223
Left Arm Collimator : 0.0649414
Left LVDT HPM :
Left LVDT VPM :
HacL_HPE1313A:0_Ch58 : -0.146484
HacL_HPE1313A:0_Ch55 : 22.8516
HacL_HPE1313A:0_Ch54 : -0.0922852
HacL_alignROLL :
HacL_alignPITCH :
HacL_alignHPT :
Right Arm Collimator : 9.76563e-05
Right LVDT HPM : 3284
Right LVDT VPM : 3869
HacR_HPE1313A:0_Ch58 : -0.558594
HacR_HPE1313A:0_Ch55 : 22.168
HacR_HPE1313A:0_Ch54 : -0.902344
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : 44.8063
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1028.6
Wien field : 29.811
Laser attenuation Hall A : 100
Laser power Hall A : 69
Half-wave plate (off=out) : OUT
rotating waveplate : 6250
Beam Half-wave plate (off=out) : OUT
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern : Quartet
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -2.06466
Arc OTR y-position : -0.139786
Arc OTR x-width : 2.96554
Arc OTR y-width : 3.03814
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Polarized 3He Target RTD #1 : 50.3223
Polarized 3He Target RTD #2 : 49.248
Polarized 3He Target RTD #3 : 52.2461
Polarized 3He Target RTD #4 : 49.1992
Polarized 3He Target RTD #5 : 41.8457
Polarized 3He Target RTD #6 : 175.605
Polarized 3He Target RTD #7 : 190.781
Polarized 3He Ref. Cell RTD #8 : 25.1953
Polarized 3He Ref. Cell RTD #9 : 25.1562
Polarized 3He Ref. Cell RTD #10 : 25.166
Polarized 3He Target Ref. Cell Gas Pres. : -20.9159
Polarized 3He Target Ref. Cell Sys.Vac. : 14.4962
Polarized 3He Target Cooling Jet : 53.1555
Polarized 3He Target OVEN RTD : 170.7
Polarized 3He Target OVEN SP1 SET : 170
Polarized 3He Target OVEN SP1 : 170
Polarized 3He Target OVEN AL1 SET : 0
Polarized 3He Target OVEN AL1 : 100
Polarized 3He Target OVEN AL1 STATUS : enabled
Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
Polarized 3He Target Half-Wave Plate STAT: 1200000
Polarized 3He Target Position (PA) : 108.881
Polarized 3He Target Position (POS) : BeO+12C LFoil
Polarized 3He Target Position (DA) : 108.881
Polarized 3He Target Position (SS9) : Axis is OK
Polarized 3He Target Position (SA10) : 0
Polarized 3He Target Position (SA9) : 0
Polarized 3He Laser#1 State : 0
Polarized 3He Laser#1 Current : 10
Polarized 3He Laser#1 Temperature : 13.2
Polarized 3He Laser#2 State : 0
Polarized 3He Laser#2 Current : 10
Polarized 3He Laser#2 Temperature : 8.9
Polarized 3He Laser#3 State : 0
Polarized 3He Laser#3 Current : 10
Polarized 3He Laser#3 Temperature : 11
Polarized 3He Laser#4 State : 2
Polarized 3He Laser#4 Current : 38
Polarized 3He Laser#4 Temperature : 14.9
Polarized 3He Laser#5 State : 13
Polarized 3He Laser#5 Current : 0
Polarized 3He Laser#5 Temperature : 0
Polarized 3He Laser#6 State : 2
Polarized 3He Laser#6 Current : 38.1
Polarized 3He Laser#6 Temperature : 9.7
Polarized 3He Laser#7 State : 2
Polarized 3He Laser#7 Current : 40
Polarized 3He Laser#7 Temperature : 9.3
Polarized 3He Coil Current Longitudinal : -6.96
Polarized 3He Coil Current Transverse : -0.045
Transverse gradient coils (A) setup current : 0
Transverse gradient coils (A) readback current : 0.000305176
Longitudinal upstream gradient coil (B) setup current : 0
Longitudinal upstream gradient coil (B) readback current : -0.0012207
Longitudinal downstream gradient coil (C) setup current : 0
Longitudinal downstream gradient coil (C) readback current : -0.000610352
Small vertical gradient coils (D) setup current : 0
Small vertical gradient coils (D) readback current : 0