User name apar
Log entry time 03:21:39 on April 23, 2003
Entry number 98198
keyword=Start_Parity_Run_2734__CODA_Config=GDH
Beginning-of-Parity-run EPICS data for Run Number 2734 at Wed Apr 23 03:21:31 EDT 2003
CODA Configuration: GDH
# Timing board information: # Integrate Time = 32.00 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 44.8063
Wien BDL : 1028.6
Wien field : 29.811
Laser attenuation Hall A : 98
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 5.53728
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.22359
Gun2: PC (PITA) NEG : 7.457
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
IA Feedback Control Hall A : disabled
IA Charge Asymmetry Hall A : -0.9
IA Timestamp Hall A : 1050613318
IA Slope Hall A : 10000
LUMI 1 HV - Ch 10 : -4.4
LUMI 2 HV - Ch 11 : -3.4
LUMI 3 HV - Ch 6 : -3.5
LUMI 4 HV - Ch 7 : -13
Left Arm Q1 momentum : 1.06695
Left Arm Q2 power supply current : 459.42
Left Arm Q2 momentum : 1.06693
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 356.569
Left Arm D1 momentum : 1.06701
Left Arm D1 NMR : 0.395023
Left Arm Q3 power supply current : 424.92
Left Arm Q3 momentum : 1.06732
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 1.14722
Right Arm Q1 gauss meter : -0.017198
Right Arm Q2 power supply current : 497.855
Right Arm Q2 momentum : 1.14726
Right Arm Q2 gauss meter : 0.2616
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 393.844
Right Arm D1 momentum : 1.14731
Right Arm D1 NMR : 0.425752
Right Arm Q3 power supply current : 537.22
Right Arm Q3 momentum : 1.1472
Right Arm Q3 gauss meter : 0.2409
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99316
Right Arm Bottom VDC voltage : 3.99561
Average current of the two cavities : 0.966413
Current on Unser monitor : -13.4146
Current on Upstream bcm : 0.978114
Current on Downstream bcm : 0.954131
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.905438
Tiefenbach Hall A energy : 1148.79
Tiefenbach Hall C energy : 4413.54
Delta(E)/E width (MV_AI_DXWID) : 3.09924
MBSY1c Hall A Beam energy : 1150.19
MBSY3c Hall C Beam energy : 4426.83
MBSY1c magnet current (amp) : 47.6444
MBSY1c Bdl : 287032
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Arm Collimator : 0.0647949
HacL_HPE1313A:0_Ch58 : -0.146484
HacL_HPE1313A:0_Ch55 : 22.8027
HacL_HPE1313A:0_Ch54 : -0.0922852
Right Arm Arm Collimator : -0.000537109
Right LVDT HPM : 3283
Right LVDT VPM : 3870
HacR_HPE1313A:0_Ch58 : -0.558594
HacR_HPE1313A:0_Ch55 : 22.168
HacR_HPE1313A:0_Ch54 : -0.900879
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -33.9
Right Arm Scattering Angle : 12.5016
IPM1C12.XPOS : 1.60164
IPM1C12.YPOS : 0.171749
IPM1H04A.XPOS : -0.31979
IPM1H04A.YPOS : -0.34938
IPM1H04B.XPOS : -1.97682
IPM1H04B.YPOS : -0.391002
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -2.06468
Arc OTR y-position : -0.139739
Arc OTR x-width : 2.96548
Arc OTR y-width : 3.03807
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out