Log entry time 23:18:31 on April 25, 2003
Entry number 98608
keyword=Start_Parity_Run_2766__CODA_Config=Injector
Beginning-of-Parity-run EPICS data for Run Number 2766 at Fri Apr 25 23:18:25 EDT 2003
CODA Configuration: Injector
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 30.1995
Wien BDL : 694.1
Wien field : 20.052
Laser attenuation Hall A : 390
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 5
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.24
Gun2: PC (PITA) NEG : 7.441
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
IA Feedback Control Hall A : disabled
IA Charge Asymmetry Hall A : -180
IA Timestamp Hall A : 1051110228
IA Slope Hall A : -180
LUMI 1 HV - Ch 10 : -4.4
LUMI 2 HV - Ch 11 : -3.4
LUMI 3 HV - Ch 6 : -3.5
LUMI 4 HV - Ch 7 : -13.8
Left Arm Q1 momentum : 7.09881e-05
Left Arm Q2 power supply current : 0.278714
Left Arm Q2 momentum : 0.000647269
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1.10746
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.170576
Left Arm Q3 power supply current : 1.99086
Left Arm Q3 momentum : 0.00500068
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.000142051
Right Arm Q1 gauss meter : -0.0001215
Right Arm Q2 power supply current : 0.22667
Right Arm Q2 momentum : 0.000526689
Right Arm Q2 gauss meter : 0.0005631
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1.97813
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.334481
Right Arm Q3 power supply current : 0.133715
Right Arm Q3 momentum : 0.000336045
Right Arm Q3 gauss meter : 0.0002628
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.98242
Right Arm Bottom VDC voltage : 3.98975
Average current of the two cavities : 0.0170235
Current on Unser monitor : -13.9534
Current on Upstream bcm : 0.0198455
Current on Downstream bcm : 0.0142016
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 12.3879
Tiefenbach Hall A energy : 1148.79
Tiefenbach Hall C energy : 4413.54
Delta(E)/E width (MV_AI_DXWID) : 0.508373
MBSY1c Hall A Beam energy : 1150.19
MBSY3c Hall C Beam energy : 5516.97
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 287032
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Arm Collimator : 0.0649902
HacL_HPE1313A:0_Ch58 : -0.144043
HacL_HPE1313A:0_Ch55 : 22.998
HacL_HPE1313A:0_Ch54 : -0.0917969
Right Arm Arm Collimator : -0.000439453
Right LVDT HPM : 3281
Right LVDT VPM : 3867
HacR_HPE1313A:0_Ch58 : -0.556152
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.897461
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -33.9
Right Arm Scattering Angle : 12.5016
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Target OTR x-position : 0.329324
Target OTR y-position : 1.33429
Target OTR x-width : 1.36902
Target OTR y-width : 1.10632
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -1.95132
Arc OTR y-position : 0.27429
Arc OTR x-width : 2.97204
Arc OTR y-width : 3.04704
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out