User name apar
Log entry time 16:05:56 on April 27, 2003
Entry number 98880
keyword=Start_Parity_Run_2796__CODA_Config=GDH
Beginning-of-Parity-run EPICS data for Run Number 2796 at Sun Apr 27 16:05:49 EDT 2003
CODA Configuration: GDH
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 30.1995
Wien BDL : 694.1
Wien field : 20.052
Laser attenuation Hall A : 156
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 5
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.224
Gun2: PC (PITA) NEG : 7.457
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
IA Feedback Control Hall A : disabled
IA Charge Asymmetry Hall A : -180
IA Timestamp Hall A : 1051110228
IA Slope Hall A : -180
LUMI 1 HV - Ch 10 : -1601.4
LUMI 2 HV - Ch 11 : -1500.6
LUMI 3 HV - Ch 6 : -1601.2
LUMI 4 HV - Ch 7 : -8.5
Left Arm Q1 momentum : 1.12552
Left Arm Q2 power supply current : 484.614
Left Arm Q2 momentum : 1.12544
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 376.445
Left Arm D1 momentum : 1.1255
Left Arm D1 NMR : 0.41667
Left Arm Q3 power supply current : 448.008
Left Arm Q3 momentum : 1.12531
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 1.1473
Right Arm Q1 gauss meter : -0.017245
Right Arm Q2 power supply current : 497.863
Right Arm Q2 momentum : 1.14728
Right Arm Q2 gauss meter : 0.2617
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 393.621
Right Arm D1 momentum : 1.1473
Right Arm D1 NMR : 0.425749
Right Arm Q3 power supply current : 537.371
Right Arm Q3 momentum : 1.14752
Right Arm Q3 gauss meter : 0.24078
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99121
Right Arm Bottom VDC voltage : 3.99756
Average current of the two cavities : 0.99917
Current on Unser monitor : -14.1772
Current on Upstream bcm : 0.99897
Current on Downstream bcm : 0.99937
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.913014
Tiefenbach Hall A energy : 1148.79
Tiefenbach Hall C energy : 4413.54
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 1150.19
MBSY3c Hall C Beam energy : 5516.97
MBSY1c magnet current (amp) : 47.6444
MBSY1c Bdl : 287032
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Arm Collimator : 0.0646973
HacL_HPE1313A:0_Ch58 : -0.146973
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : -0.0927734
Right Arm Arm Collimator : -0.000488281
Right LVDT HPM : 3282
Right LVDT VPM : 3867
HacR_HPE1313A:0_Ch58 : -0.55957
HacR_HPE1313A:0_Ch55 : 22.0703
HacR_HPE1313A:0_Ch54 : -0.900879
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -33.9
Right Arm Scattering Angle : 12.5016
IPM1C12.XPOS : 0.0574265
IPM1C12.YPOS : 0.102742
IPM1H04A.XPOS : 0.307624
IPM1H04A.YPOS : -1.07983
IPM1H04B.XPOS : 0.00192883
IPM1H04B.YPOS : -1.74355
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Target OTR x-position : 0.561239
Target OTR y-position : -2.03636
Target OTR x-width : 0.138788
Target OTR y-width : 0.288451
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -1.93579
Arc OTR y-position : 0.299896
Arc OTR x-width : 2.99809
Arc OTR y-width : 3.03833
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out