Log entry time 16:30:50 on May 6, 2003
Entry number 100489
keyword=Start_Parity_Run_2868__CODA_Config=GDH
Beginning-of-Parity-run EPICS data for Run Number 2868 at Tue May 6 16:30:41 EDT 2003
CODA Configuration: GDH
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : -25.1981
Wien BDL : -575.25
Wien field : 16.71
Laser attenuation Hall A : 218
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1500
IA Cell Setpoint Hall A : 5.05233
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.054
Gun2: PC (PITA) NEG : 7.627
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : -55.84
IA Timestamp Hall A : 1052251678
IA Slope Hall A : -408
LUMI 1 HV - Ch 10 : -4.4
LUMI 2 HV - Ch 11 : -3.4
LUMI 3 HV - Ch 6 : -3.5
LUMI 4 HV - Ch 7 : -13.8
Left Arm Q1 momentum : 0
Left Arm Q2 power supply current : 607.569
Left Arm Q2 momentum : 1.41098
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 472.75
Left Arm D1 momentum : 1.411
Left Arm D1 NMR : 0.522251
Left Arm Q3 power supply current : 561.839
Left Arm Q3 momentum : 1.41124
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.997124
Right Arm Q1 gauss meter : -0.015008
Right Arm Q2 power supply current : 497.578
Right Arm Q2 momentum : 1.14663
Right Arm Q2 gauss meter : 0.2616
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 335.639
Right Arm D1 momentum : 0.996866
Right Arm D1 NMR : 0.369925
Right Arm Q3 power supply current : 466.886
Right Arm Q3 momentum : 0.997001
Right Arm Q3 gauss meter : 0.2093
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99316
Right Arm Bottom VDC voltage : 3.99219
Average current of the two cavities : 4.04661
Current on Unser monitor : -11.271
Current on Upstream bcm : 4.04568
Current on Downstream bcm : 4.04755
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 4.09169
Tiefenbach Hall A energy : 1148.79
Tiefenbach Hall C energy : 4413.54
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 1543.2
MBSY3c Hall C Beam energy : 3049.01
MBSY1c magnet current (amp) : 64.117
MBSY1c Bdl : 385107
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Arm Collimator : 0.0648438
HacL_HPE1313A:0_Ch58 : -0.146973
HacL_HPE1313A:0_Ch55 : 22.7539
HacL_HPE1313A:0_Ch54 : -0.0952148
Right Arm Arm Collimator : -9.76563e-05
Right LVDT HPM : 3282
Right LVDT VPM : 3869
HacR_HPE1313A:0_Ch58 : -0.559082
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.906738
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -33.9
Right Arm Scattering Angle : 12.5016
IPM1C12.XPOS : -0.00504149
IPM1C12.YPOS : 0.0613414
IPM1H04A.XPOS : 0.083972
IPM1H04A.YPOS : -0.0272888
IPM1H04B.XPOS : 0.10822
IPM1H04B.YPOS : -0.108532
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -1.86985
Arc OTR y-position : 0.336294
Arc OTR x-width : 2.98778
Arc OTR y-width : 3.03135
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out