User name apar
Log entry time 05:47:29 on July 20, 2003
Entry number 105210
keyword=Start_Parity_Run_3422__CODA_Config=GDH
Beginning-of-Parity-run EPICS data for Run Number 3422 at Sun Jul 20 05:47:16 EDT 2003
CODA Configuration: GDH
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : -72.5251
Wien BDL : -1693.6
Wien field : 48.325
Laser attenuation Hall A : 393
Laser power Hall A : 71
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 5250
IA Cell Setpoint Hall A : 4.54537
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.383
Gun2: PC (PITA) NEG : 7.51843
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : -52.84
IA Timestamp Hall A : 1058691647
IA Slope Hall A : -408
LUMI 1 HV - Ch 10 : -1301.4
LUMI 2 HV - Ch 11 : -1300.5
LUMI 3 HV - Ch 6 : -701
LUMI 4 HV - Ch 7 : -7.7
Left Arm arm angle : 18.0002
Right Arm arm angle : 12.5016
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Q1 momentum : 2.07186
Left Arm Q2 power supply current : 892.097
Left Arm Q2 momentum : 2.07175
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 704.538
Left Arm D1 momentum : 2.07201
Left Arm D1 NMR : 0.7667
Left Arm Q3 power supply current : 824.912
Left Arm Q3 momentum : 2.07203
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 1.87105
Right Arm Q1 gauss meter : -0.02799
Right Arm Q2 power supply current : 811.899
Right Arm Q2 momentum : 1.87095
Right Arm Q2 gauss meter : 0.4267
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 646.146
Right Arm D1 momentum : 1.87099
Right Arm D1 NMR : 0.694304
Right Arm Q3 power supply current : 876.192
Right Arm Q3 momentum : 1.87105
Right Arm Q3 gauss meter : 0.3931
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 3.75977
Left Arm Bottom VDC Current : -1.2207
Left Arm Top VDC voltage : 4.00293
Left Arm Bottom VDC voltage : 3.99219
Right Arm Top VDC voltage : 4.00146
Right Arm Bottom VDC voltage : 4.00146
Average current of the two cavities : 1.8978
Current on Unser monitor : -12.3816
Current on Upstream bcm : 1.95196
Current on Downstream bcm : 1.84364
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 36.6268
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 2136.56
MBSY3c Hall C Beam energy : 4222.17
MBSY1c magnet current (amp) : 88.9033
MBSY1c Bdl : 533180
IPM1C12.XPOS : -0.253053
IPM1C12.YPOS : 0.0828241
IPM1H04A.XPOS : -1.01833
IPM1H04A.YPOS : -0.0414962
IPM1H04B.XPOS : -1.04956
IPM1H04B.YPOS : -0.125293
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0641602
HacL_HPE1313A:0_Ch58 : -0.140137
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : -0.102051
Right Arm Collimator : -0.000537109
Right LVDT HPM : 3213
Right LVDT VPM : 3874
HacR_HPE1313A:0_Ch58 : -0.55127
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.900391
HacR_alignROLL : -0.42005
HacR_alignPITCH : -0.00472501
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -33.9
Right Arm Scattering Angle : 12.5016
Target OTR x-position : 2.17237
Target OTR y-position : -2.291
Target OTR x-width : 0.422799
Target OTR y-width : 0.295214
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -12.9167
Arc OTR y-position : 5.44248
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Polarized 3He Target Position : Pol. He Cell
Polarized 3He Target RTD #1 : 46.3184
Polarized 3He Target RTD #2 : 54.0332
Polarized 3He Target RTD #3 : 58.3887
Polarized 3He Target RTD #4 : 54.3555
Polarized 3He Target RTD #5 : 47.9004
Polarized 3He Target RTD #6 : 211.992
Polarized 3He Target RTD #7 : 183.105
Polarized 3He Ref. Cell RTD #8 : 25.2148
Polarized 3He Ref. Cell RTD #9 : 25.1562
Polarized 3He Ref. Cell RTD #10 : 25.1855
Polarized 3He Target Ref. Cell Gas Pres. : -28.5202
Polarized 3He Target Ref. Cell Sys.Vac. : 6.79742
Polarized 3He Target Cooling Jet : 47.3877
Polarized 3He Target OVEN RTD : 170.2
Polarized 3He Target OVEN SP1 SET : 170
Polarized 3He Target OVEN SP1 : 170
Polarized 3He Target OVEN AL1 SET : 200
Polarized 3He Target OVEN AL1 : 200
Polarized 3He Target OVEN AL1 STATUS : Illegal_Value
Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
Polarized 3He Target Half-Wave Plate STAT: 1200000
Polarized 3He Target Position (PA) : 172.592
Polarized 3He Target Position (POS) : Pol. He Cell
Polarized 3He Target Position (DA) : 172.592
Polarized 3He Target Position (SS9) : Axis is OK
Polarized 3He Target Position (SA10) : 0
Polarized 3He Target Position (SA9) : 0
Polarized 3He Laser#1 State : 0
Polarized 3He Laser#1 Current : 36
Polarized 3He Laser#1 Temperature : 15.3
Polarized 3He Laser#2 State : 0
Polarized 3He Laser#2 Current : 41.4
Polarized 3He Laser#2 Temperature : 7.2
Polarized 3He Laser#3 State : 0
Polarized 3He Laser#3 Current : 38.1
Polarized 3He Laser#3 Temperature : 10.8
Polarized 3He Laser#4 State : 2
Polarized 3He Laser#4 Current : 38
Polarized 3He Laser#4 Temperature : 13.3
Polarized 3He Laser#5 State : 0
Polarized 3He Laser#5 Current : 18
Polarized 3He Laser#5 Temperature : 29
Polarized 3He Laser#6 State : 2
Polarized 3He Laser#6 Current : 38.1
Polarized 3He Laser#6 Temperature : 10.2
Polarized 3He Laser#7 State : 2
Polarized 3He Laser#7 Current : 40
Polarized 3He Laser#7 Temperature : 8
Polarized 3He Coil Current Longitudinal : -6.968
Polarized 3He Coil Current Transverse : -0.043