    User name adev

    Log entry time 00:15:21 on July 24, 2003

    Entry number 106389

    keyword=End_of_Run_22721
    ****************************
     Run Number: 22721
     End of Run Comment:
    Run_type=optics,beam_energy=1.096,beam_halfwaveplate=out,beam_raster=on,comment_text=carbon long foil, elastic kinematic,daq_mode=one HRS daq,kin_name=,leftarm_p=1.5,leftarm_theta=18.0,rightarm_p=1.094,rightarm_theta=12.502,target_halfwaveplate=out,target_name=penelope,target_polarization=37.3,target_type=BeO Carbon long foil
     
    
    PRESCALE FACTORS:ps1=16500000   ps2=10000   ps3=1   ps4=1   ps5=65535   ps8=65535   
    
    EVENTS[0]: 16723        [+]: 2188         [-]: 2182         
    TIME  [0]: 6.954 mins  [+]: 3.426 mins  [-]: 3.426 mins  
    LIVE  [0]:  98.57%      [+]:  99.41%      [-]:  99.63%      
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]: 0.0/244.2 Hz   T2[0] [PRES/REAL]: 0.0/1.8  Hz   T3[0] [PRES/REAL]: 5.7/5.7  Hz   T4[0] [PRES/REAL]: 4.9/4.9  Hz   T5[0] [PRES/REAL]: 0.0/0.0  Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[+] [PRES/REAL]: 0.0/243.8 Hz   T2[+] [PRES/REAL]: 0.0/1.7  Hz   T3[+] [PRES/REAL]: 5.9/5.9  Hz   T4[+] [PRES/REAL]: 4.8/4.8  Hz   T5[+] [PRES/REAL]: 0.0/0.0  Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[-] [PRES/REAL]: 0.0/244.6 Hz   T2[-] [PRES/REAL]: 0.0/1.8  Hz   T3[-] [PRES/REAL]: 5.6/5.6  Hz   T4[-] [PRES/REAL]: 5.0/5.0  Hz   T5[-] [PRES/REAL]: 0.0/0.0  Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:
    T1[0] [PRES/REAL]:      0/101890   T2[0] [PRES/REAL]:      0/741      T3[0] [PRES/REAL]:   2399/2399     T4[0] [PRES/REAL]:   2044/2044     T5[0] [PRES/REAL]:      0/0        T8[0] [PRES/REAL]:      6/427253   
    T1[+] [PRES/REAL]:      0/50101    T2[+] [PRES/REAL]:      0/356      T3[+] [PRES/REAL]:   1210/1210     T4[+] [PRES/REAL]:    988/988      T5[+] [PRES/REAL]:      0/0        T8[+] [PRES/REAL]:      3/210474   
    T1[-] [PRES/REAL]:      0/50278    T2[-] [PRES/REAL]:      0/376      T3[-] [PRES/REAL]:   1158/1158     T4[-] [PRES/REAL]:   1029/1029     T5[-] [PRES/REAL]:      0/0        T8[-] [PRES/REAL]:      3/210471   
    
    AVERAGE CURRENT
    BCM x1 : 0.0087 uA  BCM x3 : -0.0159uA  BCM x10: -0.0063uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :-1.291E+04 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:2.868E-05      BCM u3 [0]:-1.251E-05     BCM u10[0]:-3.421E-06     
    BCM u1 [+]:1.392E-05      BCM u3 [+]:-6.214E-06     BCM u10[+]:-1.685E-06     
    BCM u1 [-]:1.428E-05      BCM u3 [-]:-6.11E-06      BCM u10[-]:-1.683E-06     
    
    BCM d1 [0]:-2.142E-05     BCM d3 [0]:-7.351E-07     BCM d10[0]:-1.862E-06     
    BCM d1 [+]:-1.071E-05     BCM d3 [+]:-4.244E-07     BCM d10[+]:-9.341E-07     
    BCM d1 [-]:-1.042E-05     BCM d3 [-]:-2.957E-07     BCM d10[-]:-9.013E-07     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 22721 at Thu Jul 24 00:14:25 EDT 2003
    Right Arm D1 momentum : 1.127
    Right Arm arm angle : 12.5016
    Tiefenbach Hall A energy : 0
    Right Arm arm mispointing (HPT) : -0
    Right septum set current : 104.32
    Right septum current readback : 104.25
    Right Arm Q1 power supply current :
    Right Arm Q1 momentum : 1.12702
    Right Arm Q1 gauss meter : -0.016964
    Right Arm Q1 power supply polarity :
    Right Arm Q2 power supply current : 489.064
    Right Arm Q2 momentum : 1.12701
    Right Arm Q2 gauss meter : 0.257
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 385.194
    Right Arm D1 momentum : 1.127
    Right Arm D1 NMR : 0.418216
    Right Arm Q3 power supply current : 527.769
    Right Arm Q3 momentum : 1.12701
    Right Arm Q3 gauss meter : 0.2367
    Right Arm Q3 power supply polarity : disabled
    Left Arm Q1 power supply current :
    Left Arm Q1 momentum :
    Left Arm Q1 gauss meter :
    Left Arm Q1 power supply polarity :
    Left Arm Q2 power supply current :
    Left Arm Q2 momentum :
    Left Arm Q2 gauss meter :
    Left Arm Q2 power supply polarity :
    Left Arm D1 power supply current :
    Left Arm D1 momentum :
    Left Arm D1 NMR :
    Left Arm Q3 power supply current :
    Left Arm Q3 momentum :
    Left Arm Q3 gauss meter :
    Left Arm Q3 power supply polarity :
    Average current of the two cavities : 0.0159305
    Current on Unser monitor : -13.9975
    Current on Upstream bcm : 0.017306
    Current on Downstream bcm : 0.014555
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143715
    MBSY1c Hall A Beam energy : 1096.81
    MBSY1c magnet current (amp) : 45.4045
    MBSY1c Bdl : 273711
    MBSY3c Hall C Beam energy : 5261.06
    HALLA:p : 2134.16
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 0
    Tiefenbach Hall C energy : 0
    Delta(E)/E width (MV_AI_DXWID) : 0.457621
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Right Arm Arm Collimator : -0.000683594
    Left Arm Arm Collimator :
    HacR_HPE1313A:0_Ch58 : -0.556641
    HacR_HPE1313A:0_Ch55 : 22.2168
    HacR_HPE1313A:0_Ch54 : -0.902832
    HacR_alignROLL : -0.423288
    HacR_alignPITCH : 9.36389e-05
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 :
    HacL_HPE1313A:0_Ch55 :
    HacL_HPE1313A:0_Ch54 :
    HacL_alignROLL :
    HacL_alignPITCH :
    HacL_alignHPT :
    Right Arm Arm Collimator : -0.000537109
    Left Arm Arm Collimator :
    Wien angle : -72.5251
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -1700.6
    Wien field : 48.325
    Laser attenuation Hall A : 193
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    rotating waveplate : 7000
    Beam Half-wave plate (off=out) : OUT
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : No Delay
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : No Delay
    G0 Helicity Pattern : Quartet
    OTR x-position : -7.9589
    OTR y-position : 7.73516
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : No
    Polarized 3He Target RTD #1 : 49.7363
    Polarized 3He Target RTD #2 : 57.2266
    Polarized 3He Target RTD #3 : 82.1875
    Polarized 3He Target RTD #4 : 74.1406
    Polarized 3He Target RTD #5 : 49.9512
    Polarized 3He Target RTD #6 : 203.027
    Polarized 3He Target RTD #7 : 173.203
    Polarized 3He Ref. Cell RTD #8 : 72.959
    Polarized 3He Ref. Cell RTD #9 : 27.8027
    Polarized 3He Ref. Cell RTD #10 : 25.166
    Polarized 3He Target Ref. Cell Gas Pres. : 85.2991
    Polarized 3He Target Ref. Cell Sys.Vac. : 1102.46
    Polarized 3He Target Cooling Jet : 48.2117
    Polarized 3He Target OVEN RTD : 170
    Polarized 3He Target OVEN SP1 SET : 170
    Polarized 3He Target OVEN SP1 : 170
    Polarized 3He Target OVEN AL1 SET : 200
    Polarized 3He Target OVEN AL1 : 200
    Polarized 3He Target OVEN AL1 STATUS : Illegal_Value
    Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
    Polarized 3He Target Half-Wave Plate STAT: 1200000
    Polarized 3He Target Position (PA) : 12.3308
    Polarized 3He Target Position (POS) : Empty Target
    Polarized 3He Target Position (DA) : 12.3309
    Polarized 3He Target Position (SS9) : Axis is OK
    Polarized 3He Target Position (SA10) : 0
    Polarized 3He Target Position (SA9) : 0
    Polarized 3He Laser#1 State : 0
    Polarized 3He Laser#1 Current : 36
    Polarized 3He Laser#1 Temperature : 14.8
    Polarized 3He Laser#2 State : 0
    Polarized 3He Laser#2 Current : 41.4
    Polarized 3He Laser#2 Temperature : 8.5
    Polarized 3He Laser#3 State : 0
    Polarized 3He Laser#3 Current : 38.1
    Polarized 3He Laser#3 Temperature : 11.4
    Polarized 3He Laser#4 State : 2
    Polarized 3He Laser#4 Current : 38
    Polarized 3He Laser#4 Temperature : 13.3
    Polarized 3He Laser#5 State : 0
    Polarized 3He Laser#5 Current : 18
    Polarized 3He Laser#5 Temperature : 29
    Polarized 3He Laser#6 State : 2
    Polarized 3He Laser#6 Current : 38.1
    Polarized 3He Laser#6 Temperature : 10.2
    Polarized 3He Laser#7 State : 2
    Polarized 3He Laser#7 Current : 40
    Polarized 3He Laser#7 Temperature : 8
    Polarized 3He Coil Current Longitudinal : -6.957
    Polarized 3He Coil Current Transverse : -0.043
    Transverse gradient coils (A) setup current : 0
    Transverse gradient coils (A) readback current : 0.000915527
    Longitudinal upstream gradient coil (B) setup current : 0
    Longitudinal upstream gradient coil (B) readback current : 0.00640869
    Longitudinal downstream gradient coil (C) setup current : 0
    Longitudinal downstream gradient coil (C) readback current : -0.000915527
    Small vertical gradient coils (D) setup current : 0
    Small vertical gradient coils (D) readback current : 0
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : Current is Low
    Arc OTR x-position : -2.74596
    Arc OTR y-position : -0.0431485
    Arc OTR x-width : 3.62865
    Arc OTR y-width : 1.93909
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out