Log entry time 20:19:40 on July 24, 2003
Entry number 106629
keyword=End_of_Parity_Run_3613__CODA_Config=GDH
End-of-Parity-run EPICS data for Run Number 3613 at Thu Jul 24 20:19:25 EDT 2003
CODA Configuration: GDH
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : -72.5251
Wien BDL : -1700.6
Wien field : 48.325
Laser attenuation Hall A : 216
Laser power Hall A : 71
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 7000
IA Cell Setpoint Hall A : 8.81517
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.383
Gun2: PC (PITA) NEG : 7.51843
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : 162.24
IA Timestamp Hall A : 1059092264
IA Slope Hall A : -408
LUMI 1 HV - Ch 10 : -1501.4
LUMI 2 HV - Ch 11 : -1300.5
LUMI 3 HV - Ch 6 : -2.7
LUMI 4 HV - Ch 7 : -13.8
Left Arm arm angle : 0
Right Arm arm angle : 12.5016
Left Arm arm mispointing (HPT) : 0
Right Arm arm mispointing (HPT) : -0
Left Arm Q1 momentum : 0.743742
Left Arm Q2 power supply current : 320.359
Left Arm Q2 momentum : 0.743982
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 247.802
Left Arm D1 momentum : 0.744
Left Arm D1 NMR : 0.275516
Left Arm Q3 power supply current : 296.226
Left Arm Q3 momentum : 0.744065
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.951918
Right Arm Q1 gauss meter : -0.014376
Right Arm Q2 power supply current : 413.071
Right Arm Q2 momentum : 0.951886
Right Arm Q2 gauss meter : 0.2171
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 324.694
Right Arm D1 momentum : 0.951995
Right Arm D1 NMR : 0.353274
Right Arm Q3 power supply current : 445.778
Right Arm Q3 momentum : 0.951928
Right Arm Q3 gauss meter : 0.1997
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -2.29492
Left Arm Bottom VDC Current : -2.19727
Left Arm Top VDC voltage : 3.99463
Left Arm Bottom VDC voltage : 3.99609
Right Arm Top VDC voltage : 4.00342
Right Arm Bottom VDC voltage : 3.99756
Average current of the two cavities : 1.00253
Current on Unser monitor : -14.6099
Current on Upstream bcm : 1.02985
Current on Downstream bcm : 1.01104
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 86.8572
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
Delta(E)/E width (MV_AI_DXWID) : 3.18493
MBSY1c Hall A Beam energy : 1096.81
MBSY3c Hall C Beam energy : 5261.06
MBSY1c magnet current (amp) : 45.4045
MBSY1c Bdl : 273711
IPM1C12.XPOS : -0.741065
IPM1C12.YPOS : 0.136653
IPM1H04A.XPOS : 0.0238736
IPM1H04A.YPOS : 0.0220049
IPM1H04B.XPOS : -0.0561684
IPM1H04B.YPOS : -0.0176232
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0581543
HacL_HPE1313A:0_Ch58 : -0.135742
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.0893555
Right Arm Collimator : -0.000146484
Right LVDT HPM : 3278
Right LVDT VPM : 3869
HacR_HPE1313A:0_Ch58 : -0.557129
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.904297
HacR_alignROLL : -0.424329
HacR_alignPITCH : 0.000159651
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -33.9
Right Arm Scattering Angle : 12.5016
Target OTR x-position : 3.35735
Target OTR y-position : -1.53576
Target OTR x-width : 0.163375
Target OTR y-width : 0.195769
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -2.48732
Arc OTR y-position : -0.148755
Arc OTR x-width : 3.62005
Arc OTR y-width : 1.91936
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Polarized 3He Target Position : BeO+12C Foils
Polarized 3He Target RTD #1 : 47.5293
Polarized 3He Target RTD #2 : 53.4961
Polarized 3He Target RTD #3 : 57.5488
Polarized 3He Target RTD #4 : 70.4199
Polarized 3He Target RTD #5 : 56.0352
Polarized 3He Target RTD #6 : 203.262
Polarized 3He Target RTD #7 : 174.961
Polarized 3He Ref. Cell RTD #8 : 72.9688
Polarized 3He Ref. Cell RTD #9 : 29.043
Polarized 3He Ref. Cell RTD #10 : 25.4688
Polarized 3He Target Ref. Cell Gas Pres. : -31.5251
Polarized 3He Target Ref. Cell Sys.Vac. : 6.35928
Polarized 3He Target Cooling Jet : 73.2056
Polarized 3He Target OVEN RTD : 169.8
Polarized 3He Target OVEN SP1 SET : 170
Polarized 3He Target OVEN SP1 : 170
Polarized 3He Target OVEN AL1 SET : 200
Polarized 3He Target OVEN AL1 : 200
Polarized 3He Target OVEN AL1 STATUS : Illegal_Value
Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
Polarized 3He Target Half-Wave Plate STAT: 1200000
Polarized 3He Target Position (PA) : 83.8102
Polarized 3He Target Position (POS) : BeO+12C Foils
Polarized 3He Target Position (DA) : 83.8103
Polarized 3He Target Position (SS9) : Axis is OK
Polarized 3He Target Position (SA10) : 0
Polarized 3He Target Position (SA9) : 0
Polarized 3He Laser#1 State : 0
Polarized 3He Laser#1 Current : 36
Polarized 3He Laser#1 Temperature : 14.8
Polarized 3He Laser#2 State : 0
Polarized 3He Laser#2 Current : 41.4
Polarized 3He Laser#2 Temperature : 8.5
Polarized 3He Laser#3 State : 0
Polarized 3He Laser#3 Current : 38.1
Polarized 3He Laser#3 Temperature : 11.4
Polarized 3He Laser#4 State : 2
Polarized 3He Laser#4 Current : 38
Polarized 3He Laser#4 Temperature : 13.3
Polarized 3He Laser#5 State : 0
Polarized 3He Laser#5 Current : 18
Polarized 3He Laser#5 Temperature : 29
Polarized 3He Laser#6 State : 2
Polarized 3He Laser#6 Current : 38.1
Polarized 3He Laser#6 Temperature : 10.2
Polarized 3He Laser#7 State : 2
Polarized 3He Laser#7 Current : 40
Polarized 3He Laser#7 Temperature : 8
Polarized 3He Coil Current Longitudinal : -6.954
Polarized 3He Coil Current Transverse : -0.044