• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Armstrong

    Log entry time 21:13:30 on July30,2003

    Entry number 108222

    Followups:

    keyword=Target Temperature Study (NMR)

    18:34    Start Target Temperature study (as instructed
    by Vince). Lasers 4,6,7 turned off. Wait for oven temperature to
    stabilize.

    I should have done an NMR measurement first, to get a baseline
    before turning the lasers off...


    18:58    Do NMR, lasers off, 3He cell position.

    Result: 36.79% (using laser off number)

    19:01    Turn on Laser 4
    19:02    Turn on Laser 6
    19:03    Turn on Laser 7

        waiting for temperatures to stabilize...

    19:22    Do NMR, lasers on, 3He cell position.

    Result: 38.06% (using laser on number)
    19:23    Lasers 4,6,7 turned off

        waiting for temperatures to stabilize...

    19:42    Do NMR, lasers off, 3He cell position.

    Result: 36.27% (using laser off number)

    19:45    Turn on Laser 4
    19:46    Turn on Laser 6
    19:47    Turn on Laser 7

        waiting for temperatures to stabilize...

    20:14    Do NMR, lasers on, 3He cell position.

    Result: 37.54% (using laser on number)
    20:16    Lasers 4,6,7 turned off

        waiting for temperatures to stabilize...

    20:40    Do NMR, lasers off, 3He cell position.

    Result: 35.65% (using laser off number)

    20:41    Turn on Laser 4
    20:42    Turn on Laser 6
    20:44    Turn on Laser 7

        waiting for temperatures to stabilize...

    20:14    Do NMR, lasers on, 3He cell position.
    oops.. I hit the Go button a second time
    on the NMR screen, and since I don't know how to elegantly abort the routine, I
    end up with two NMRs in a row. Ouch.


    Result (of the 2nd NMR) : 36.11% (using laser on number)

    Now, I'll let the target quietly pump back up...

    Striptool of target temperatures during this procedure is below.



    FIGURE 1