• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Reitz

    Log entry time 08:53:24 on August 1,2003

    Entry number 108417

    This entry is a followup to: 108401

    keyword=beamline HV

    seems that someone turned off the HV in the whole "beamline HV crate":
    the green light on the upper left corner of the screen was off, one has to press
    this button to turn on all used channels.
    The HVs in this crate are not needed for HRS data taking, but for beamline
    instrumentation:
    Slot 1, Ch0/Ch1 are for the SuperHarps in the ARC (for ARC energy measurements)
    Slot 1, Ch2-Ch5 are for ep system (off, if not needed)
    Slot 1, Ch6 ???? (should be spare for ep, but someone else is using it)
    Slot 1, Ch7 spare ep
    Slot 1, Ch8/Ch9 are for ep system (off, if not needed)
    Slot 1, Ch10/Ch11 Lumi Monitors
    Slot 2, Ch0/Ch1 are for ep system (off, if not needed)
    Slot 3, all Channels for ep system (off, if not needed), label Moeller is wrong
    other Slots are for Moeller, Compton, etc