User name Glashausser
Log entry time 16:29:28 on August 9,2003
Entry number 109750
keyword=8/9/03 day run summary
8AM Smoothly running Kin 8.10 angle 0, beam hwp in 10 microamp
8:47 change to beam hwp out (Kin 8.10 continuing)
8:52 tgt position drifts. Beam off to move tgt so MCC can fix.
9:20 MCC still trying to get tgt position right
9:35 position OK check spot size with raster on.
9:40 spot OK move 3He tgt back in.
9:50 Beam back start run 2335/3335 at 10 micro
10:50 Finish Beam HWP out measurements for tgt angle 0
11:00 Tgt NMR polarization measurement : 36.06%
11:05 Rotating holding field
Hall C bleed-through measurement 1.48% (of our beam)
(Last measure of Hall C polar was -50+/- 5%)
11:20 Beam back and tgt unmasked-- Start Run 3338 (Tgt angle 270,
beam hwp out)
12:10 Put Beam hwp back in
13:07 Kin 8.10 completed
(Last two runs both stopped prematurely when beam position shift of .5-1mm noted. MCC doesn't understand these shifts with fast feedback on.)
Holding field angle changed to 0
Tgt changed to single C foil
13:45 Magnet now set, just as MCC finishes machine diagnostic
Start C single foil run--first part of Kin 8.11
Beam hwp IN
14:22 Finish setting septum (with C foil).
Putting in empty reference cell. Raster on.
Will do checks on position.
14:40 MCC says sudden shifts in beam position are caused by stopping and starting Hall C beam. Correlation not explained.
15:06 Back to standard position of reference cell. Fill with N2.
(Lowering position of reference cell by 3mm did not change
count rate significantly.)
15:54 Start 3He production--run 3351, beam HWP IN, 0deg