User name apar
Log entry time 05:15:04 on August 14, 2003
Entry number 110596
keyword=End_of_Parity_Run_3873__CODA_Config=GDH
End-of-Parity-run EPICS data for Run Number 3873 at Thu Aug 14 05:14:50 EDT 2003
CODA Configuration: GDH
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 30.1995
Wien BDL : 694.82
Wien field : 20.052
Laser attenuation Hall A : 125
Laser power Hall A : 71
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 7000
IA Cell Setpoint Hall A : 6.3277
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.008
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.596
Gun2: PC (PITA) NEG : 7.305
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : -29.12
IA Timestamp Hall A : 1060852249
IA Slope Hall A : -408
LUMI 1 HV - Ch 10 : -1301.4
LUMI 2 HV - Ch 11 : -1300.5
LUMI 3 HV - Ch 6 : -2.7
LUMI 4 HV - Ch 7 : -13.8
Left Arm arm angle : 17.9997
Right Arm arm angle : 17.9999
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Q1 momentum : 1.11913
Left Arm Q2 power supply current : 481.876
Left Arm Q2 momentum : 1.11908
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 373.199
Left Arm D1 momentum : 1.11892
Left Arm D1 NMR : 0.414236
Left Arm Q3 power supply current : 445.456
Left Arm Q3 momentum : 1.1189
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 1.108
Right Arm Q1 gauss meter : -0.016062
Right Arm Q2 power supply current : 476.849
Right Arm Q2 momentum : 1.10766
Right Arm Q2 gauss meter : 0.2507
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 378.789
Right Arm D1 momentum : 1.108
Right Arm D1 NMR : 0.411164
Right Arm Q3 power supply current : 505.048
Right Arm Q3 momentum : 1.10824
Right Arm Q3 gauss meter : 0.2264
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 4.58984
Left Arm Bottom VDC Current : 3.90625
Left Arm Top VDC voltage : 3.98779
Left Arm Bottom VDC voltage : 3.99854
Right Arm Top VDC voltage : 4.00195
Right Arm Bottom VDC voltage : 3.99756
Average current of the two cavities : 0.0163077
Current on Unser monitor : -14.736
Current on Upstream bcm : 0.0175153
Current on Downstream bcm : 0.0151001
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143715
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
Delta(E)/E width (MV_AI_DXWID) : 0.803712
MBSY1c Hall A Beam energy : 1148.23
MBSY3c Hall C Beam energy : 5507.49
MBSY1c magnet current (amp) : 47.5619
MBSY1c Bdl : 286542
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0.048395
IPM1H04A.YPOS : -0.024507
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.057373
HacL_HPE1313A:0_Ch58 : -0.135254
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.0844727
Right Arm Collimator : -0.000244141
Right LVDT HPM : 3292
Right LVDT VPM : 3877
HacR_HPE1313A:0_Ch58 : -0.524414
HacR_HPE1313A:0_Ch55 : 22.4609
HacR_HPE1313A:0_Ch54 : -0.822266
HacR_alignROLL : -0.34173
HacR_alignPITCH : -0.0297941
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 18
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 17.9999
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -2.91523
Arc OTR y-position : 0.00356029
Arc OTR x-width : 3.62996
Arc OTR y-width : 1.94134
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Polarized 3He Target Position : BeO+12C Foils
Polarized 3He Target RTD #1 : 45.0879
Polarized 3He Target RTD #2 : 53.0371
Polarized 3He Target RTD #3 : 60.4492
Polarized 3He Target RTD #4 : 67.7441
Polarized 3He Target RTD #5 : 52.1387
Polarized 3He Target RTD #6 : 214.219
Polarized 3He Target RTD #7 : 173.906
Polarized 3He Ref. Cell RTD #8 : 72.5488
Polarized 3He Ref. Cell RTD #9 : 34.9023
Polarized 3He Ref. Cell RTD #10 : 22.5879
Polarized 3He Target Ref. Cell Gas Pres. : -27.8456
Polarized 3He Target Ref. Cell Sys.Vac. : 7.42334
Polarized 3He Target Cooling Jet : 73.5535
Polarized 3He Target OVEN RTD : 169.5
Polarized 3He Target OVEN SP1 SET : 170
Polarized 3He Target OVEN SP1 : 170
Polarized 3He Target OVEN AL1 SET : 200
Polarized 3He Target OVEN AL1 : 200
Polarized 3He Target OVEN AL1 STATUS : Illegal_Value
Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
Polarized 3He Target Half-Wave Plate STAT: 1200000
Polarized 3He Target Position (PA) : 83.8102
Polarized 3He Target Position (POS) : BeO+12C Foils
Polarized 3He Target Position (DA) : 83.8103
Polarized 3He Target Position (SS9) : Axis is OK
Polarized 3He Target Position (SA10) : 0
Polarized 3He Target Position (SA9) : 0
Polarized 3He Laser#1 State : 0
Polarized 3He Laser#1 Current : 36
Polarized 3He Laser#1 Temperature : 14.8
Polarized 3He Laser#2 State : 0
Polarized 3He Laser#2 Current : 41.4
Polarized 3He Laser#2 Temperature : 8.5
Polarized 3He Laser#3 State : 0
Polarized 3He Laser#3 Current : 38.1
Polarized 3He Laser#3 Temperature : 11.4
Polarized 3He Laser#4 State : 0
Polarized 3He Laser#4 Current : 18
Polarized 3He Laser#4 Temperature : 28
Polarized 3He Laser#5 State : 2
Polarized 3He Laser#5 Current : 37.5
Polarized 3He Laser#5 Temperature : 17.5
Polarized 3He Laser#6 State : 2
Polarized 3He Laser#6 Current : 38.1
Polarized 3He Laser#6 Temperature : 10.2
Polarized 3He Laser#7 State : 2
Polarized 3He Laser#7 Current : 40
Polarized 3He Laser#7 Temperature : 8
Polarized 3He Coil Current Longitudinal : -6.979
Polarized 3He Coil Current Transverse : -0.044