Runs 23646 through 23650 were taken to examine the influence of adjusting the gain (HV) of S2m's PMTs on the timing resolution. They were taken at varying HV settings.
As a result, the HV on many of the channels has been reduced such that the primary signal is only between 50 and 70cnts above the pedestal.
FIGURE 1