Twice tonight... TS1 failed to respond, and the TS1 console in the "components" screen showed that there was an exception error, and we could not do a "soft" reboot (by typing reboot, or doing a Ctrl-X).
Both times, we were able to bring runcontrol back to normal by reboot the crate via the Slow Controls. Then in the runcontrol GUI: "Cancel", "Reset", then "Download".