• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Moffit

    Log entry time 06:14:13 on August18,2003

    Entry number 111755

    keyword=Target: NMR = 42.3% + wierd

    05:44 Perform NMR 05:47 Turn off long. lasers Rotate holding field to 270° 05:53 Turn on T1 05:55 Turn on T2 05:57 Turn on T3 NMR = 42.3% (Jaideep) these were the last two NMR measurements. time septum width height pol 0100 289.50 59 mG 17.26 41.09% 0553 267.50 56 mG 17.78 42.32% somehow the pol has gone up? we even did an EPR at 0100 as well and got 40.8%. since last NMR we had 3 hrs of no beam on Pol 3He target and about 2 hrs of fairly stable 5 microA on Pol 3He. is this real or is this a lineshape issue? the magic 8 ball says "signs point to yes." i'm still skeptical. the magic eight agrees that i'm still skeptical.