• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name J. Singh

    Log entry time 06:58:30 on August19,2003

    Entry number 111875

    keyword=septum training time info

    for future reference:

    ramping the septum from 0A to 250A took 1 hr @ at ramp voltage of 115mV.

    ramping the septum from 250A to 414A took 3 hrs @ a ramp voltage of 115mV.

    ramping the septum from 414A to 427A took 20 min @ a ramp voltage of 120mV.

    recovering (both coil temps 7K or less) from a septum training quench @ 427A took 7 hrs.

    see fig 1. the black curve is septum read current


    FIGURE 1