    User name Sulkosky

    Log entry time 16:57:00 on August19,2003

    Entry number 111886

    keyword=EPR AFP Loss Tests

    EPR AFP loss tests I


    Septum Iread = 349.5A


    Correction Coil C = 1.9A


    Correction Coil D = -1.9A



    --------------------------------

    Results from 0th order fit:

    time Down shift Up shift
    11:29 43.2% 42.6%
    11:31 42.2% 41.9%
    11:33 41.8% 41.5%
    11:35 41.2% 40.6%
    11:37 40.8% 40.4%

    Total loss for five measurements = 2.3%

    Absolute loss = 0.256%/sweep

    Relative loss = 0.59%/sweep

    ----------------------------------------

    Results from 1st order fit:

    Total loss for five measurements = 2.62%

    Absolute loss = 0.291%/sweep

    Relative loss = 0.68%/sweep






    EPR AFP loss tests II


    Septum Iread = 397.75A


    Correction Coil C = 2.2A


    Correction Coil D = -2.2A



    --------------------------------

    Results from 0th order fit:

    time Down shift Up shift
    11:29 39.2% 38.9%
    11:31 39.1% 38.4%
    11:33 38.2% 37.5%
    11:35 37.4% 37.2%
    11:37 36.7% 36.5%

    Total loss for five measurements = 2.45%


    Absolute loss = 0.272%/sweep


    Relative loss = 0.69%/sweep

    ----------------------------------------

    Results from 1st order fit:

    Total loss for five measurements = 2.65%

    Absolute loss = 0.294%/sweep

    Relative loss = 0.75%/sweep


    Note: Using the vertical correction coils for EPR helps lower the AFP loss at high Septum currents. At 400A on the Septum and no correction, the EPR AFP loss is about 2.3%/sweep (relative).