Log entry time 00:28:33 on August 21, 2003
Entry number 112303
keyword=End_of_Parity_Run_3948__CODA_Config=GDH
End-of-Parity-run EPICS data for Run Number 3948 at Thu Aug 21 00:28:18 EDT 2003
CODA Configuration: GDH
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 33.9007
Wien BDL : 779.44
Wien field : 22.525
Laser attenuation Hall A : 561
Laser power Hall A : 71
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 7000
IA Cell Setpoint Hall A : 1.27703
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.008
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.596
Gun2: PC (PITA) NEG : 7.305
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : -8.12
IA Timestamp Hall A : 1061439910
IA Slope Hall A : -408
LUMI 1 HV - Ch 10 : -1301.4
LUMI 2 HV - Ch 11 : -1300.5
LUMI 3 HV - Ch 6 : -3.5
LUMI 4 HV - Ch 7 : -13.8
Left Arm arm angle : 17.9997
Right Arm arm angle : 17.9999
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Q1 momentum : 2.16996
Left Arm Q2 power supply current : 934.393
Left Arm Q2 momentum : 2.16998
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 740.349
Left Arm D1 momentum : 2.16996
Left Arm D1 NMR : 0.802924
Left Arm Q3 power supply current : 863.823
Left Arm Q3 momentum : 2.16976
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 1.21791
Right Arm Q1 gauss meter : -0.017664
Right Arm Q2 power supply current : 524.5
Right Arm Q2 momentum : 1.21835
Right Arm Q2 gauss meter : 0.2757
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 416.066
Right Arm D1 momentum : 1.218
Right Arm D1 NMR : 0.451984
Right Arm Q3 power supply current : 554.894
Right Arm Q3 momentum : 1.21762
Right Arm Q3 gauss meter : 0.249
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -2.34375
Left Arm Bottom VDC Current : -2.05078
Left Arm Top VDC voltage : 3.98682
Left Arm Bottom VDC voltage : 3.99805
Right Arm Top VDC voltage : 4.00244
Right Arm Bottom VDC voltage : 3.99707
Average current of the two cavities : 10.1771
Current on Unser monitor : -5.58369
Current on Upstream bcm : 10.2729
Current on Downstream bcm : 10.0813
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 78.5943
Tiefenbach Hall A energy : 2233.9
Tiefenbach Hall C energy : 5491.68
Delta(E)/E width (MV_AI_DXWID) : 1.0877
MBSY1c Hall A Beam energy : 2235.91
MBSY3c Hall C Beam energy : 5507.49
MBSY1c magnet current (amp) : 93.0459
MBSY1c Bdl : 557973
IPM1C12.XPOS : -1.07605
IPM1C12.YPOS : 0.0663133
IPM1H04A.XPOS : -0.0315188
IPM1H04A.YPOS : -0.0351396
IPM1H04B.XPOS : -0.0207946
IPM1H04B.YPOS : -0.0740479
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0572754
HacL_HPE1313A:0_Ch58 : -0.133301
HacL_HPE1313A:0_Ch55 : 24.5117
HacL_HPE1313A:0_Ch54 : -0.0947266
Right Arm Collimator : -0.000292969
Right LVDT HPM : 3299
Right LVDT VPM : 3891
HacR_HPE1313A:0_Ch58 : -0.518555
HacR_HPE1313A:0_Ch55 : 23.3398
HacR_HPE1313A:0_Ch54 : -0.80127
HacR_alignROLL : -0.319482
HacR_alignPITCH : -0.036833
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 18
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 17.9999
Target OTR x-position : 2.87363
Target OTR y-position : -1.98763
Target OTR x-width : 0.820151
Target OTR y-width : 0.72946
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -2.1914
Arc OTR y-position : 0.0104294
Arc OTR x-width : 3.58429
Arc OTR y-width : 1.8086
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Polarized 3He Target Position : Pol. He Cell
Polarized 3He Target RTD #1 : 46.8262
Polarized 3He Target RTD #2 : 53.9746
Polarized 3He Target RTD #3 : 65.8105
Polarized 3He Target RTD #4 : 77.9199
Polarized 3He Target RTD #5 : 56.6504
Polarized 3He Target RTD #6 : 211.289
Polarized 3He Target RTD #7 : 174.609
Polarized 3He Ref. Cell RTD #8 : 69.9316
Polarized 3He Ref. Cell RTD #9 : 32.5195
Polarized 3He Ref. Cell RTD #10 : 22.7051
Polarized 3He Target Ref. Cell Gas Pres. : -30.7279
Polarized 3He Target Ref. Cell Sys.Vac. : 11.617
Polarized 3He Target Cooling Jet : 74.9268
Polarized 3He Target OVEN RTD : 169.9
Polarized 3He Target OVEN SP1 SET : 170
Polarized 3He Target OVEN SP1 : 170
Polarized 3He Target OVEN AL1 SET : 200
Polarized 3He Target OVEN AL1 : 200
Polarized 3He Target OVEN AL1 STATUS : Illegal_Value
Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
Polarized 3He Target Half-Wave Plate STAT: 1200000
Polarized 3He Target Position (PA) : 174.973
Polarized 3He Target Position (POS) : Pol. He Cell
Polarized 3He Target Position (DA) : 174.973
Polarized 3He Target Position (SS9) : Axis is OK
Polarized 3He Target Position (SA10) : 0
Polarized 3He Target Position (SA9) : 0
Polarized 3He Laser#1 State : 0
Polarized 3He Laser#1 Current : 36
Polarized 3He Laser#1 Temperature : 14.8
Polarized 3He Laser#2 State : 0
Polarized 3He Laser#2 Current : 41.4
Polarized 3He Laser#2 Temperature : 8.5
Polarized 3He Laser#3 State : 0
Polarized 3He Laser#3 Current : 38
Polarized 3He Laser#3 Temperature : 11.4
Polarized 3He Laser#4 State : 0
Polarized 3He Laser#4 Current : 18
Polarized 3He Laser#4 Temperature : 28
Polarized 3He Laser#5 State : 2
Polarized 3He Laser#5 Current : 37.5
Polarized 3He Laser#5 Temperature : 17.5
Polarized 3He Laser#6 State : 2
Polarized 3He Laser#6 Current : 38.1
Polarized 3He Laser#6 Temperature : 10.2
Polarized 3He Laser#7 State : 2
Polarized 3He Laser#7 Current : 40
Polarized 3He Laser#7 Temperature : 8
Polarized 3He Coil Current Longitudinal : -6.939
Polarized 3He Coil Current Transverse : -0.044