Log entry time 06:38:05 on August 21, 2003
Entry number 112374
keyword=Start_Parity_Run_3953__CODA_Config=GDH
Beginning-of-Parity-run EPICS data for Run Number 3953 at Thu Aug 21 06:37:50 EDT 2003
CODA Configuration: GDH
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 33.9007
Wien BDL : 779.44
Wien field : 22.525
Laser attenuation Hall A : 453
Laser power Hall A : 71
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 7000
IA Cell Setpoint Hall A : 1.31838
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.008
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.596
Gun2: PC (PITA) NEG : 7.305
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : -34.03
IA Timestamp Hall A : 1061462070
IA Slope Hall A : -408
LUMI 1 HV - Ch 10 : -1301.4
LUMI 2 HV - Ch 11 : -1300.5
LUMI 3 HV - Ch 6 : -2.7
LUMI 4 HV - Ch 7 : -13.8
Left Arm arm angle : 17.9997
Right Arm arm angle : 17.9999
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Q1 momentum : 2.16996
Left Arm Q2 power supply current : 934.322
Left Arm Q2 momentum : 2.16981
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 740.324
Left Arm D1 momentum : 2.16991
Left Arm D1 NMR : 0.802905
Left Arm Q3 power supply current : 863.968
Left Arm Q3 momentum : 2.17013
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 1.04402
Right Arm Q1 gauss meter : -0.015147
Right Arm Q2 power supply current : 449.431
Right Arm Q2 momentum : 1.04397
Right Arm Q2 gauss meter : 0.2362
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 356.233
Right Arm D1 momentum : 1.044
Right Arm D1 NMR : 0.387415
Right Arm Q3 power supply current : 475.76
Right Arm Q3 momentum : 1.04397
Right Arm Q3 gauss meter : 0.2133
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 3.80859
Left Arm Bottom VDC Current : -1.2207
Left Arm Top VDC voltage : 3.99512
Left Arm Bottom VDC voltage : 3.99561
Right Arm Top VDC voltage : 4.00244
Right Arm Bottom VDC voltage : 3.99902
Average current of the two cavities : 9.66945
Current on Unser monitor : -5.71728
Current on Upstream bcm : 9.75121
Current on Downstream bcm : 9.58768
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 44.8462
Tiefenbach Hall A energy : 2234.05
Tiefenbach Hall C energy : 5491.69
Delta(E)/E width (MV_AI_DXWID) : 4.47793
MBSY1c Hall A Beam energy : 2235.91
MBSY3c Hall C Beam energy : 5507.49
MBSY1c magnet current (amp) : 93.0459
MBSY1c Bdl : 557973
IPM1C12.XPOS : -1.39628
IPM1C12.YPOS : 0.0149813
IPM1H04A.XPOS : -0.00628949
IPM1H04A.YPOS : 0.0694064
IPM1H04B.XPOS : -0.0031024
IPM1H04B.YPOS : -0.0246991
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0570801
HacL_HPE1313A:0_Ch58 : -0.133301
HacL_HPE1313A:0_Ch55 : 24.5605
HacL_HPE1313A:0_Ch54 : -0.0947266
Right Arm Collimator : -0.000537109
Right LVDT HPM : 3298
Right LVDT VPM : 3890
HacR_HPE1313A:0_Ch58 : -0.518555
HacR_HPE1313A:0_Ch55 : 23.3398
HacR_HPE1313A:0_Ch54 : -0.800781
HacR_alignROLL : -0.318931
HacR_alignPITCH : -0.0355528
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 18
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 17.9999
Target OTR x-position : 3.24765
Target OTR y-position : -1.76334
Target OTR x-width : 0.533352
Target OTR y-width : 0.627798
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -2.27101
Arc OTR y-position : 0.0373968
Arc OTR x-width : 3.607
Arc OTR y-width : 1.81245
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Polarized 3He Target Position : Pol. He Cell
Polarized 3He Target RTD #1 : 46.8457
Polarized 3He Target RTD #2 : 54.043
Polarized 3He Target RTD #3 : 65.957
Polarized 3He Target RTD #4 : 78.1543
Polarized 3He Target RTD #5 : 56.6895
Polarized 3He Target RTD #6 : 211.23
Polarized 3He Target RTD #7 : 174.785
Polarized 3He Ref. Cell RTD #8 : 70.0488
Polarized 3He Ref. Cell RTD #9 : 33.5449
Polarized 3He Ref. Cell RTD #10 : 22.6953
Polarized 3He Target Ref. Cell Gas Pres. : -28.5815
Polarized 3He Target Ref. Cell Sys.Vac. : 17.2502
Polarized 3He Target Cooling Jet : 78.0579
Polarized 3He Target OVEN RTD : 169.7
Polarized 3He Target OVEN SP1 SET : 170
Polarized 3He Target OVEN SP1 : 170
Polarized 3He Target OVEN AL1 SET : 200
Polarized 3He Target OVEN AL1 : 200
Polarized 3He Target OVEN AL1 STATUS : Illegal_Value
Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
Polarized 3He Target Half-Wave Plate STAT: 1200000
Polarized 3He Target Position (PA) : 174.973
Polarized 3He Target Position (POS) : Pol. He Cell
Polarized 3He Target Position (DA) : 174.973
Polarized 3He Target Position (SS9) : Axis is OK
Polarized 3He Target Position (SA10) : 0
Polarized 3He Target Position (SA9) : 0
Polarized 3He Laser#1 State : 0
Polarized 3He Laser#1 Current : 36
Polarized 3He Laser#1 Temperature : 14.8
Polarized 3He Laser#2 State : 0
Polarized 3He Laser#2 Current : 41.4
Polarized 3He Laser#2 Temperature : 8.5
Polarized 3He Laser#3 State : 0
Polarized 3He Laser#3 Current : 38
Polarized 3He Laser#3 Temperature : 11.4
Polarized 3He Laser#4 State : 0
Polarized 3He Laser#4 Current : 18
Polarized 3He Laser#4 Temperature : 28
Polarized 3He Laser#5 State : 2
Polarized 3He Laser#5 Current : 37.5
Polarized 3He Laser#5 Temperature : 17.5
Polarized 3He Laser#6 State : 2
Polarized 3He Laser#6 Current : 38.1
Polarized 3He Laser#6 Temperature : 10.2
Polarized 3He Laser#7 State : 2
Polarized 3He Laser#7 Current : 40
Polarized 3He Laser#7 Temperature : 8
Polarized 3He Coil Current Longitudinal : -6.923
Polarized 3He Coil Current Transverse : -0.044