    User name Sulkosky

    Log entry time 20:29:56 on August22,2003

    Entry number 112713

    keyword=Target Strip Charts

    Figure 1 shows the target temperature strip chart during the last 10 hours. Figure 2 shows the Helmholtz coil currents for the last 10 hours. Looking at both the coil currents and temperatures the configurations for the lasers and holding field appear normal and correspond to the configurations run during the Day and early part of the Swing Shift. I have found no reason so far for the large polarization loss seen after the controlled access. The other possible cause could be traced to turning the correction coils on in the reference cell position. The gradients are not known in this position. The turning on of the coils may have induced a large gradient that was not anticipated.


    FIGURE 1

    FIGURE 2