    keyword=Ytg Spectrum for Kin. 12.16.5

    Figure 1 shows the ytg spectrum for Kinematic 12.16.5, Right P0 = 1.919 GeV/c, Septum Iread = 243.5A. The central foil is close to zero. For this Kinematic and the next 12.17, I noticed that the Septum current is 1A too low. I will notify the shift crew to correct this for future Kinematics, since the set point and read back currents are off by ~ 1A at between 200 and 300A on the Septum magnet.

    Below are the results from the physics replay:

    y_tg center from max is at -0.749999 +/- 0.5 mm.
    y_tg center from fit is at -0.748896 mm.



    FIGURE 1