Main INDEX
Monthly INDEX
PREV
NEXT
User name apar
Log entry time 08:02:14 on August 26, 2003
Entry number 113557
keyword=Start_Parity_Run_4006__CODA_Config=GDH
Beginning-of-Parity-run EPICS data for Run Number 4006 at Tue Aug 26 08:02:00 EDT 2003
CODA Configuration: GDH
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 43.6058
Wien BDL : 1006.5
Wien field : 29.009
Laser attenuation Hall A : 291
Laser power Hall A : 71
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 7000
IA Cell Setpoint Hall A : 1.18451
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.008
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.596
Gun2: PC (PITA) NEG : 7.305
G0 Helicity Settle Set : 1
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : 17.25
IA Timestamp Hall A : 1061897080
IA Slope Hall A : -408
LUMI 1 HV - Ch 10 : -1301.4
LUMI 2 HV - Ch 11 : -1300.5
LUMI 3 HV - Ch 6 : -2.7
LUMI 4 HV - Ch 7 : -13.8
Left Arm arm angle : 17.9997
Right Arm arm angle : 0
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : 0
Left Arm Q1 momentum : 2.81191
Left Arm Q2 power supply current : 1210.68
Left Arm Q2 momentum : 2.81162
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 977.726
Left Arm D1 momentum : 2.81194
Left Arm D1 NMR : 1.04106
Left Arm Q3 power supply current : 1.95338
Left Arm Q3 momentum : 0.00490654
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 3.10409
Right Arm Q1 gauss meter : -0.04455
Right Arm Q2 power supply current : 1336.38
Right Arm Q2 momentum : 3.10424
Right Arm Q2 gauss meter : 0.7015
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1117.87
Right Arm D1 momentum : 3.10399
Right Arm D1 NMR : 1.15185
Right Arm Q3 power supply current : 1414.35
Right Arm Q3 momentum : 3.10356
Right Arm Q3 gauss meter : 0.6346
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -2.29492
Left Arm Bottom VDC Current : 3.61328
Left Arm Top VDC voltage : 3.99072
Left Arm Bottom VDC voltage : 3.99756
Right Arm Top VDC voltage : 3.99365
Right Arm Bottom VDC voltage : 3.99414
Average current of the two cavities : 4.93542
Current on Unser monitor : -11.2905
Current on Upstream bcm : 4.9514
Current on Downstream bcm : 4.91943
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 95.1016
Tiefenbach Hall A energy : 3318.99
Tiefenbach Hall C energy : 5488.88
Delta(E)/E width (MV_AI_DXWID) : 1.34022
MBSY1c Hall A Beam energy : 3324.14
MBSY3c Hall C Beam energy : 5504.68
MBSY1c magnet current (amp) : 138.432
MBSY1c Bdl : 829544
IPM1C12.XPOS : -0.0855426
IPM1C12.YPOS : 0.0288435
IPM1H04A.XPOS : -0.119971
IPM1H04A.YPOS : 0.0486335
IPM1H04B.XPOS : -0.0384078
IPM1H04B.YPOS : 0.0608738
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0570313
HacL_HPE1313A:0_Ch58 : -0.133789
HacL_HPE1313A:0_Ch55 : 25.9766
HacL_HPE1313A:0_Ch54 : -0.0976562
Right Arm Collimator : -0.000732422
Right LVDT HPM : 3308
Right LVDT VPM : 3909
HacR_HPE1313A:0_Ch58 : -0.504883
HacR_HPE1313A:0_Ch55 : 24.8047
HacR_HPE1313A:0_Ch54 : -0.779785
HacR_alignROLL : 0
HacR_alignPITCH : 0
HacR_alignHPT : 0
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0
Target OTR x-position : 3.67369
Target OTR y-position : -1.2237
Target OTR x-width : 0.204385
Target OTR y-width : 0.344149
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -2.48278
Arc OTR y-position : -0.187371
Arc OTR x-width : 3.62099
Arc OTR y-width : 1.91629
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Polarized 3He Target Position : BeO+12C Foils
Polarized 3He Target RTD #1 : 47.5195
Polarized 3He Target RTD #2 : 56.4941
Polarized 3He Target RTD #3 : 61.6992
Polarized 3He Target RTD #4 : 68.9551
Polarized 3He Target RTD #5 : 55.6543
Polarized 3He Target RTD #6 : 213.164
Polarized 3He Target RTD #7 : 178.359
Polarized 3He Ref. Cell RTD #8 : 68.7598
Polarized 3He Ref. Cell RTD #9 : 36.0742
Polarized 3He Ref. Cell RTD #10 : 21.4844
Polarized 3He Target Ref. Cell Gas Pres. : -35.7566
Polarized 3He Target Ref. Cell Sys.Vac. : 7.36075
Polarized 3He Target Cooling Jet : 72.5281
Polarized 3He Target OVEN RTD : 170.1
Polarized 3He Target OVEN SP1 SET : 170
Polarized 3He Target OVEN SP1 : 170
Polarized 3He Target OVEN AL1 SET : 200
Polarized 3He Target OVEN AL1 : 200
Polarized 3He Target OVEN AL1 STATUS : Illegal_Value
Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
Polarized 3He Target Half-Wave Plate STAT: 1200000
Polarized 3He Target Position (PA) : 83.8102
Polarized 3He Target Position (POS) : BeO+12C Foils
Polarized 3He Target Position (DA) : 83.8103
Polarized 3He Target Position (SS9) : Axis is OK
Polarized 3He Target Position (SA10) : 0
Polarized 3He Target Position (SA9) : 0
Polarized 3He Laser#1 State : 0
Polarized 3He Laser#1 Current : 36
Polarized 3He Laser#1 Temperature : 14.8
Polarized 3He Laser#2 State : 0
Polarized 3He Laser#2 Current : 41.4
Polarized 3He Laser#2 Temperature : 8.5
Polarized 3He Laser#3 State : 0
Polarized 3He Laser#3 Current : 38
Polarized 3He Laser#3 Temperature : 11.4
Polarized 3He Laser#4 State : 0
Polarized 3He Laser#4 Current : 18
Polarized 3He Laser#4 Temperature : 28
Polarized 3He Laser#5 State : 2
Polarized 3He Laser#5 Current : 37.5
Polarized 3He Laser#5 Temperature : 17.5
Polarized 3He Laser#6 State : 2
Polarized 3He Laser#6 Current : 38.1
Polarized 3He Laser#6 Temperature : 10.2
Polarized 3He Laser#7 State : 2
Polarized 3He Laser#7 Current : 40
Polarized 3He Laser#7 Temperature : 8
Polarized 3He Coil Current Longitudinal : -6.875
Polarized 3He Coil Current Transverse : -0.044