NEXT
User name a-onl
Log entry time 18:36:55 on December 16, 2003
Entry number 114525
keyword=Start_Run_1381,Run_type=other,beam_energy=3.318,beam_halfwaveplate=in,beam_raster=on,comment_text=cosmics run,daq_mode=TWOARM,kin_name=,leftarm_p=0.0,leftarm_theta=6,rightarm_p=0.0,rightarm_theta=6,target_halfwaveplate=out,target_name=priapus,target_polarization=42.5,target_type=Empty
Beginning-of-run EPICS data for Run Number 1381 at Tue Dec 16 18:36:27 EST 2003
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; PS1 for main R-arm trigger.
; PS2 for R-arm 2/3 effic. trigger
; PS3 for main L-arm trigger.
; PS4 for L-arm 2/3 effic. trigger
; PS5 for coincidence scintillator trigger
; PS6 for pure Kaon trigger (L-arm)
; PS7 for coincidence of T1 and T6.
; PS8 for 1024 Hz pulser ( put ps=65535 normally )
; At present (Dec 8) there are only T1, T3, T8
ps1=1,ps2=50,ps3=1,ps4=50,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right septum set current : 200
Right septum current readback : 212.25
Right Arm Q1 power supply current :
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : -9.76e-05
Right Arm Q1 power supply polarity :
Right Arm Q2 power supply current : 0.245372
Right Arm Q2 momentum : 0.000565439
Right Arm Q2 gauss meter : -0.0002254
Right Arm Q2 power supply polarity :
Right Arm D1 power supply current : 1.63723
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.440871
Right Arm Q3 power supply current : 0.0974993
Right Arm Q3 momentum : 0.000208203
Right Arm Q3 gauss meter : -0.0001596
Right Arm Q3 power supply polarity : enabled
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Right Arm Top VDC voltage : 4.00098
Right Arm Bottom VDC voltage : 4.00439
Average current of the two cavities : 0.0203157
Current on Unser monitor : -2.04797
Current on Upstream bcm : 0.0106615
Current on Downstream bcm : 0.0300893
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 40.559
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
Delta(E)/E width (MV_AI_DXWID) : 0.790392
HALLA:p : 0
HALLA:dpp : 0
MBSY1c Hall A Beam energy : 2039.67
MBSY3c Hall C Beam energy : 3037.12
MBSY1c magnet current (amp) : 84.8559
MBSY1c Bdl : 509001
Arc1 dp/p : 0
Arc2 dp/p : 0
Right Arm Arm Collimator : -0.000390625
Right LVDT HPM : 3287
Right LVDT VPM : 3860
HacR_HPE1313A:0_Ch58 : -0.546387
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -0.893066
HacR_alignROLL : -0.413936
HacR_alignPITCH : -0.00873485
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : -9.69575
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -230.86
Wien field : 6.3498
Laser attenuation Hall A : 60
Laser power Hall A : 67
Half-wave plate (off=out) : OUT
rotating waveplate : 6200
Beam Half-wave plate (off=out) : OUT
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern : Quartet
Target OTR x-position :
Target OTR y-position :
Target OTR x-width :
Target OTR y-width :
Target OTR data valid flag :
Target OTR In/Out :
Arc OTR x-position : 0.00381432
Arc OTR y-position : -2.31671
Arc OTR x-width : 3.017
Arc OTR y-width : 1.14261
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Polarized 3He Coil Current Longitudinal :
Polarized 3He Coil Current Transverse :
Transverse gradient coils (A) setup current : 0
Transverse gradient coils (A) readback current : 0
Longitudinal upstream gradient coil (B) setup current : 0
Longitudinal upstream gradient coil (B) readback current : 0
Longitudinal downstream gradient coil (C) setup current : 0
Longitudinal downstream gradient coil (C) readback current : 0
Small vertical gradient coils (D) setup current : 0
Small vertical gradient coils (D) readback current : 0