Main INDEX
Monthly INDEX
PREV
NEXT
User name reitz
Log entry time 23:04:19 on December23,2003
Entry number 115112
keyword=rich tests part 2
2) p0 = 2105 MeV/c, C12 (thick), 15uA, T3=22kHz, I(VDC)=0
1568 withrich HV2050/600/16ns, I(RICH) = 0.08, 15uA, T3=22khz
1569 withrich HV2120/250/16ns, I(RICH) = 0.11, 15uA, T3=22khz
runs fine, no trip after 20 min
3) p0 = 2080 MeV/c, C12 (thick), 15uA, I(VDC)=0
RICH tripped while going from 2105 to 2080
but after the magnets settle, it is stable at 2120/250/16ns,
with I(RICH)=0.13
4) p0 = 2095 MeV/c, C12 (thick), 15uA, I(VDC)=0, T3=26khz
RICH tripped while going from 2080 to 2095,
but is stable once magnets at 2120/250/16ns,
1573 withrich HV2120/250/16ns, I(RICH) = 0.13, 15uA, T3=26khz
this methode is too slow
we will do it by tuning dipole alone and by hand