    User name a-onl

    Log entry time 15:46:39 on January 10, 2004

    Entry number 115462

    keyword=End_of_Run_1691
    ****************************
     Run Number: 1691
     End of Run Comment:
    Run_type=cosmics,beam_energy=2.035,beam_halfwaveplate=in,beam_raster=off,comment_text=cosmics,daq_mode=TWOARM,kin_name=,leftarm_p=0,leftarm_theta=6,rightarm_p=0,rightarm_theta=6,target_halfwaveplate=out,target_name=priapus,target_polarization=42.5,target_type=Empty
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1   ps4=2   ps5=1   ps6=1   ps7=9999   ps8=65535   
    
    EVENTS[0]: 23452        [+]: 11578        [-]: 11548        
    TIME  [0]: 15.060 mins  [+]: 7.420 mins  [-]: 7.418 mins  
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  94.85%      [+]:  94.91%      [-]:  94.90%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 9.2/9.2  Hz   T2[0] : 4.9/4.9  Hz   T3[0] : 9.3/9.3  Hz   T4[0] : 5.8/11.5 Hz   T5[0] : 3.1/3.1  Hz   T6[0] : 1.2/1.2  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 9.2/9.2  Hz   T2[+] : 4.9/4.9  Hz   T3[+] : 9.2/9.2  Hz   T4[+] : 5.8/11.6 Hz   T5[+] : 3.0/3.0  Hz   T6[+] : 1.2/1.2  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 9.2/9.2  Hz   T2[-] : 4.9/4.9  Hz   T3[-] : 9.4/9.4  Hz   T4[-] : 5.8/11.5 Hz   T5[-] : 3.1/3.1  Hz   T6[-] : 1.2/1.2  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8302/8302     T2[0] :   4436/4436     T3[0] :   8415/8415     T4[0] :   5212/10424    T5[0] :   2757/2757     T6[0] :   1104/1104     T7[0] :      0/14       T8[0] :     14/925270   
    T1[+] :   4095/4095     T2[+] :   2199/2199     T3[+] :   4117/4117     T4[+] :   2572/5144     T5[+] :   1342/1342     T6[+] :    552/552      T7[+] :      0/6        T8[+] :      6/455864   
    T1[-] :   4086/4086     T2[-] :   2176/2176     T3[-] :   4172/4172     T4[-] :   2564/5129     T5[-] :   1372/1372     T6[-] :    537/537      T7[-] :      0/8        T8[-] :      6/455740   
    
    AVERAGE CURRENT
    BCM x1 : 0.1131 uA  BCM x3 : 0.0122 uA  BCM x10: -0.0107uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -4389 ppm     BCM u3 :    -9071 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    -7749 ppm     BCM d3 :    1E+39 ppm     BCM d10:    1E+39 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0001212      BCM u3 [0]:2.613E-05      BCM u10[0]:-8.601E-06     
    BCM u1 [+]:5.945E-05      BCM u3 [+]:1.275E-05      BCM u10[+]:-4.265E-06     
    BCM u1 [-]:5.996E-05      BCM u3 [-]:1.298E-05      BCM u10[-]:-4.206E-06     
    
    BCM d1 [0]:8.323E-05      BCM d3 [0]:-4.133E-06     BCM d10[0]:-1.065E-05     
    BCM d1 [+]:4.07E-05       BCM d3 [+]:-2.128E-06     BCM d10[+]:-5.274E-06     
    BCM d1 [-]:4.132E-05      BCM d3 [-]:-1.959E-06     BCM d10[-]:-5.222E-06     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1691 at Sat Jan 10 15:43:31 EST 2004
    Left Arm D1 momentum : 0.510001
    Left Arm arm angle : 0
    Right Arm D1 momentum : 0.509996
    Right Arm arm angle : 0
    HALLA:p : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. 4020.92
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 4020.92
    Left Arm arm mispointing (HPT) :
    Right Arm arm mispointing (HPT) : 0
    Left Arm Top VDC Current : 2.97852
    Left Arm Bottom VDC Current : 3.71094
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Left septum set current : 0
    Left septum current readback : -3
    Left septum upper coil T : 6.1
    Left septum lower coil T : 5.9
    Left septum yoke T : 4.9
    Left septum bore shield T : 79.8
    Left Arm Q1 power supply current :
    Left Arm Q1 momentum : 0.509877
    Left Arm Q1 gauss meter :
    Left Arm Q1 power supply polarity :
    Left Arm Q2 power supply current : 221.248
    Left Arm Q2 momentum : 0.509846
    Left Arm Q2 gauss meter :
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 171.325
    Left Arm D1 momentum : 0.51
    Left Arm D1 NMR : 0.18894
    Left Arm Q3 power supply current : 238.758
    Left Arm Q3 momentum : 0.509851
    Left Arm Q3 gauss meter :
    Left Arm Q3 power supply polarity : enabled
    Right septum set current : 0
    Right septum current readback : 0
    Right septum upper coil T : 6.1
    Right septum lower coil T : 6.7
    Right septum yoke T : 5.3
    Right septum bore shield T : 17.6
    Right Arm Q1 power supply current :
    Right Arm Q1 momentum : 0.510042
    Right Arm Q1 gauss meter : -0.007657
    Right Arm Q1 power supply polarity :
    Right Arm Q2 power supply current : 221.269
    Right Arm Q2 momentum :
    Right Arm Q2 gauss meter : 0.116
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 175.625
    Right Arm D1 momentum : 0.51
    Right Arm D1 NMR : 0.189255
    Right Arm Q3 power supply current : 238.729
    Right Arm Q3 momentum : 0.509789
    Right Arm Q3 gauss meter : 0.10642
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0285163
    Current on Unser monitor : -4.84272
    Current on Upstream bcm : 0.0200749
    Current on Downstream bcm : 0.0370506
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143715
    Hall C Current :
    MBSY1c Hall A Beam energy : 4028.55
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 1.00533e+06
    MBSY3c Hall C Beam energy : 3038.72
    Tiefenbach Hall A energy : 4020.92
    Tiefenbach Hall C energy : 3030.8
    Delta(E)/E width (MV_AI_DXWID) : 3.60916
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.0577148
    Left LVDT HPM :
    Left LVDT VPM :
    HacL_HPE1313A:0_Ch58 : -0.19043
    HacL_HPE1313A:0_Ch55 : 23.4375
    HacL_HPE1313A:0_Ch54 : 0.0561523
    HacL_alignROLL :
    HacL_alignPITCH :
    HacL_alignHPT :
    Right Arm Collimator : -0.000537109
    Right LVDT HPM : 3287
    Right LVDT VPM : 3860
    HacR_HPE1313A:0_Ch58 : -0.550781
    HacR_HPE1313A:0_Ch55 : 21.7773
    HacR_HPE1313A:0_Ch54 : -0.88916
    HacR_alignROLL : 0
    HacR_alignPITCH : 0
    HacR_alignHPT : 0
    Wien angle : -9.50155
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -221.6
    Wien field : 6.22
    Laser attenuation Hall A : 330
    Laser power Hall A : 100
    Half-wave plate (off=out) : OFF
    rotating waveplate : 6117
    Beam Half-wave plate (off=out) : OUT
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : 8 cycles
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : 8 cycles
    G0 Helicity Pattern : Quartet
    Target OTR x-position :
    Target OTR y-position :
    Target OTR x-width :
    Target OTR y-width :
    Target OTR data valid flag :
    Target OTR In/Out :
    Arc OTR x-position : -12.9167
    Arc OTR y-position : 5.44248
    Arc OTR x-width : 0
    Arc OTR y-width : -0
    Arc OTR data valid flag : No
    Arc OTR In/Out : Current is Low
    RICH Vmon 16 : 2054.4
    RICH Imon 16 : 0.04
    RICH Vmon 17 : 251.4
    RICH Imon 17 : 0.01
    RICH Radiator Oxygen : -0.488281
    RICH Radiator Moisture : 489.16
    RICH Radiator Pressure : 9.6333
    RICH Condensor temperature : -228.762
    RICH Gas Oxygen : 26.9531
    RICH Gas Moisture : 4.49219
    RICH Argon Flow : 0.878906
    RICH Methane Flow : 499.023
    RICH A Volts : 3.80859
    RICH B Volts : -3.90869
    RICH Purity Monitor filename :
    SLI data valid? :
    SLI horiz size mm :
    SLI Energy spread *10^5 :
    SLI x position :