    User name Breuer

    Log entry time 00:15:44 on January28,2004

    Entry number 116942

    keyword=Running shift summary 16:00-24:00


    16:00
    17:10 called MCC for status: doing Harp scans right now to
    diagnose ongoing beam trip problem
    18:03 beam ready, move in waterfall target
    ask for rastered 60 uA beam
    18:06 get 61 uA beam, start run 2193
    after run modify prescalers for next run
    18:18 start run 2194; notice that OTR "data valid: no"
    informed operator who will work on it.
    18:40 OTR gives valid results; but width in y~0.34mm and in
    x ~ 0.2
    decide to tolerate this since the cooldown period is soon
    18:58 Rich HV tripped, stop run, reset HV, start new run

    Harp Scan done at 17:16 (Elog entry 1192665
    IHAIC12: sigma-x = 0.141, sigma-y = 0.099
    We will not do a further Harp scan before recooling entry at 20:00.

    BPM-B at -0.01 /-0.08 (19:30)

    NOTE: left septum was set
    183.50 instead of 183.31 A
    19:59 start ramping down left septum; ARM and Ed Faults go
    into Hall to recool septum
    ~21:45 beam permit, starting to ramp up magnet
    ~22:50 MCC askes for C target for harp scan, go to Carbon target
    22:20: MCC is finished with Harp scans, moving waterfall
    target back in

    Harp scan results:
    1C12
    7.4699998330325 uA CW MODE (DC) (IBCxxxxCRCUR2)
    Raw Data File: IHA1C12.01272004_22:08
    x sig: 0.1445 +/- 0.0085
    u sig: 0.0978 +/- 0.0063
    y sig: 0.0292 +/- 0.0013

    22:23: left septum ready, target ready, ask for 60 uA, rastered
    22:27, after starting run 2198, asked MCC if they could reduce
    width seen on OTR; values are same as before cooling shutdown
    22:33: OTR: sigma-x= 0.125, sigma-y=0.220 (two days ago 0.07/0.16)
    Operator volonteered to call optics expert for advice.

    NOTE: OTR is right after HARP, but does not necessarily give
    same reading, needs to be cross calibrated; Operator changed
    a filter, which changed the readings from 0.21/0.33 to 0.13/0.22
    without changes to the beam.
    With the current settings, used for 60 uA beam on Waterfall target,
    we get the following corresponding values:

    OTR sigma x/y Harp sigma x/y
    0.125 / 0.220 0.145 / 0.030
    (yes, y is a factor of 7 different)


    ~22:48 Noticed that left septum magnet was not at full current
    as requested (readback was ~178 A) ; stopped run;
    reentered curent value; now PS current is 182.5,
    Magnet current is 183.5 A.

    23:54 beam unstable, MCC wants retuning, putting in Carbon target
    ~0005 move waterfall target back in; get beam

    looks like septa IOC don't communicate "Keep alive status" red;
    ask for beam off since we don't see temperature

    ~00:00 reboot coda; ROCS 12 and 16 needed rebooting;

    runs:
    2193 Waterfall,
    2194 Waterfall, prescalers have been changed
    2195 Waterfall, Rich tripped shortly before end of run
    2196 Waterfall
    2197 Waterfall start at 19:27
    2198 Waterfall start at 22:26, 60 uA; left Septum current ~ 5A too low
    2199 Waterfall start at 22:52
    2200 Waterfall start at 23:21 run stopped acquiring ~23:40 without
    visible error message; running at a couple