Main INDEX
Monthly INDEX
PREV
NEXT
User name apar
Log entry time 08:26:10 on March 18, 2004
Entry number 117360
keyword=Start_Parity_Run_1220__CODA_Config=TestCrate
Beginning-of-Parity-run EPICS data for Run Number 1220 at Thu Mar 18 08:25:54 EST 2004
CODA Configuration: TestCrate
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 11.4958
Wien BDL : 276.39
Wien field : 7.5529
Laser attenuation Hall A : 0
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 0
IA Cell Setpoint Hall A : 5
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.42
Gun2: PC (PITA) NEG : 7.371
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
IA Feedback Control Hall A :
IA Charge Asymmetry Hall A :
IA Timestamp Hall A :
IA Slope Hall A :
Back LUMI 3 HV - Ch 10 : -500
Back LUMI 7 HV - Ch 11 : -750
Left Arm arm angle : 0
Right Arm arm angle : 0
Left Arm arm mispointing (HPT) : 0
Right Arm arm mispointing (HPT) : 0
Left Arm Q1 momentum : 0
Left Arm Q2 power supply current : 0.000153479
Left Arm Q2 momentum : 3.53679e-07
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 0.00278475
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.311237
Left Arm Q3 power supply current : -1.8717e-05
Left Arm Q3 momentum : -3.99687e-08
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : -2.67e-05
Right Arm Q2 power supply current : -1598.99
Right Arm Q2 momentum : -3.68474
Right Arm Q2 gauss meter : -0.0002732
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0087003
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.232351
Right Arm Q3 power supply current : -0.00063194
Right Arm Q3 momentum : -1.34946e-06
Right Arm Q3 gauss meter : -0.0002146
Right Arm Q3 power supply polarity : enabled
Left Arm Top VDC Current : 0.585938
Left Arm Bottom VDC Current : 0.634766
Left Arm Top VDC voltage : 0.00976562
Left Arm Bottom VDC voltage : 0.0107422
Right Arm Top VDC voltage : 4
Right Arm Bottom VDC voltage : 4.00342
Average current of the two cavities : 0.0283081
Current on Unser monitor : -4.7996
Current on Upstream bcm : 0.0245553
Current on Downstream bcm : 0.0320609
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143715
Tiefenbach Hall A energy : 3775.63
Tiefenbach Hall C energy : 3030.01
Delta(E)/E width (MV_AI_DXWID) : 14.0439
MBSY1c Hall A Beam energy : 3782.39
MBSY3c Hall C Beam energy : 3037.93
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 943901
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.057959
HacL_HPE1313A:0_Ch58 : -0.190918
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : 0.0571289
Right Arm Collimator : -0.000292969
Right LVDT HPM : 3292
Right LVDT VPM : 3850
HacR_HPE1313A:0_Ch58 : -0.555176
HacR_HPE1313A:0_Ch55 : 21.3867
HacR_HPE1313A:0_Ch54 : -0.895996
HacR_alignROLL : 0
HacR_alignPITCH : 0
HacR_alignHPT : 0
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0
Target OTR x-position :
Target OTR y-position :
Target OTR x-width :
Target OTR y-width :
Target OTR data valid flag :
Target OTR In/Out :
Arc OTR x-position : -1.43538
Arc OTR y-position : -2.22113
Arc OTR x-width : 2.92592
Arc OTR y-width : 2.20686
Arc OTR data valid flag : No
Arc OTR In/Out : Sources adc bin bob crl doc lib pan tmp tst