Log entry time 10:23:34 on April 14, 2004
Entry number 117902
keyword=End_of_Parity_Run_1408__CODA_Config=Lumi
End-of-Parity-run EPICS data for Run Number 1408 at Wed Apr 14 10:23:18 EDT 2004
CODA Configuration: Lumi
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 2.49577
Wien BDL : 56.795
Wien field : 1.5373
Laser attenuation Hall A : 60
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 6150
IA Cell Setpoint Hall A : 4.238
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.65
Gun2: PC (PITA) NEG : 7.1
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
IA Feedback Control Hall A :
IA Charge Asymmetry Hall A :
IA Timestamp Hall A :
IA Slope Hall A :
Back LUMI 3 HV - Ch 10 : -500
Back LUMI 7 HV - Ch 11 : -750
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Q1 momentum : 0
Left Arm Q2 power supply current : 0.330834
Left Arm Q2 momentum : 0.000762378
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 1.10069
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.238717
Left Arm Q3 power supply current : 1.96435
Left Arm Q3 momentum : 0.00419473
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.00017868
Right Arm Q1 gauss meter : -0.0001161
Right Arm Q2 power supply current : 0.239493
Right Arm Q2 momentum : 0.000551891
Right Arm Q2 gauss meter : -0.0001362
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1.97892
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.322814
Right Arm Q3 power supply current : 0.237762
Right Arm Q3 momentum : 0.000507723
Right Arm Q3 gauss meter : -0.000105
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 1.5625
Left Arm Bottom VDC Current : -0.0488281
Left Arm Top VDC voltage : 3.98242
Left Arm Bottom VDC voltage : 4.00146
Right Arm Top VDC voltage : 4.00244
Right Arm Bottom VDC voltage : 4.0083
Average current of the two cavities : 0.0278677
Current on Unser monitor : -6.09337
Current on Upstream bcm : 0.0207666
Current on Downstream bcm : 0.0349688
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143715
Tiefenbach Hall A energy : 3776.03
Tiefenbach Hall C energy : 3030.37
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3782.79
MBSY3c Hall C Beam energy : 3038.29
MBSY1c magnet current (amp) : 5.08079e-06
MBSY1c Bdl : 944001
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0575684
HacL_HPE1313A:0_Ch58 : -0.17334
HacL_HPE1313A:0_Ch55 : 23.0469
HacL_HPE1313A:0_Ch54 : 0.0620117
Right Arm Collimator : -0.000146484
Right LVDT HPM : 3287
Right LVDT VPM : 3859
HacR_HPE1313A:0_Ch58 : -0.544922
HacR_HPE1313A:0_Ch55 : 21.7285
HacR_HPE1313A:0_Ch54 : -0.886719
HacR_alignROLL : -0.407642
HacR_alignPITCH : -0.00994837
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Target OTR x-position :
Target OTR y-position :
Target OTR x-width :
Target OTR y-width :
Target OTR data valid flag :
Target OTR In/Out :
Arc OTR x-position : -1.20897
Arc OTR y-position : -129.59
Arc OTR x-width : 1.32053
Arc OTR y-width : 29.4584
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out