User name apar
Log entry time 18:23:16 on April 16, 2004
Entry number 118109
keyword=Start_Parity_Run_1459__CODA_Config=GDH
Beginning-of-Parity-run EPICS data for Run Number 1459 at Fri Apr 16 18:23:06 EDT 2004
CODA Configuration: GDH
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 2.49577
Wien BDL : 64.655
Wien field : 1.5373
Laser attenuation Hall A : 88
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 7745
IA Cell Setpoint Hall A : 5
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.45
Gun2: PC (PITA) NEG : 7.35
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
LUMI HV - Ch 0 : -675.8
LUMI HV - Ch 1 : -700.6
LUMI HV - Ch 2 : -565.8
LUMI HV - Ch 3 : -650.7
LUMI HV - Ch 4 : -810.3
LUMI HV - Ch 5 : -700.9
LUMI HV - Ch 6 : -702.1
LUMI HV - Ch 7 : -701.7
LUMI HV - Ch 8 : -964
LUMI HV - Ch 9 : -902.5
LUMI HV - Ch 10 : -7.6
LUMI HV - Ch 11 : -12.3
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Q1 momentum : 1.96
Left Arm Q2 power supply current : 850.696
Left Arm Q2 momentum : 1.96035
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 664.994
Left Arm D1 momentum : 1.95999
Left Arm D1 NMR : 0.725274
Left Arm Q3 power supply current : 917.798
Left Arm Q3 momentum : 1.95989
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 1.56988
Right Arm Q1 gauss meter : -0.02334
Right Arm Q2 power supply current : 681.321
Right Arm Q2 momentum : 1.57005
Right Arm Q2 gauss meter : 0.3581
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 539.985
Right Arm D1 momentum : 1.57
Right Arm D1 NMR : 0.582606
Right Arm Q3 power supply current : 735.18
Right Arm Q3 momentum : 1.56992
Right Arm Q3 gauss meter : 0.3299
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current :
Left Arm Bottom VDC Current :
Left Arm Top VDC voltage :
Left Arm Bottom VDC voltage :
Right Arm Top VDC voltage : 3.49854
Right Arm Bottom VDC voltage : 3.49707
Average current of the two cavities : 4.54251
Current on Unser monitor : -1.48755
Current on Upstream bcm : 4.53644
Current on Downstream bcm : 4.54857
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 4.65369
Tiefenbach Hall A energy : 3775.67
Tiefenbach Hall C energy : 3030.37
Delta(E)/E width (MV_AI_DXWID) : 1.88406
MBSY1c Hall A Beam energy : 3783.6
MBSY3c Hall C Beam energy : 3038.29
MBSY1c magnet current (amp) : 157.639
MBSY1c Bdl : 944201
IPM1C12.XPOS : 0.961819
IPM1C12.YPOS : -0.0227766
IPM1H04A.XPOS : 4.04745
IPM1H04A.YPOS : 0.273229
IPM1H04B.XPOS : 0.269474
IPM1H04B.YPOS : 0.0832814
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0571777
HacL_HPE1313A:0_Ch58 : -0.17334
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : 0.0512695
Right Arm Collimator : -0.000585938
Right LVDT HPM : 3289
Right LVDT VPM : 3865
HacR_HPE1313A:0_Ch58 : -0.541992
HacR_HPE1313A:0_Ch55 : 21.9238
HacR_HPE1313A:0_Ch54 : -0.885254
HacR_alignROLL : -0.405939
HacR_alignPITCH : -0.0129059
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Arc OTR x-position : 0.0737575
Arc OTR y-position : 1.13492
Arc OTR x-width : 1.7145
Arc OTR y-width : 1.67572
Arc OTR data valid flag : No
Arc OTR In/Out : Sources adc bin bob crl doc lib pan tmp tst
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
Encoder position : 3303568
temperature loop 1 : 93.8
temperature loop 1 : 99.99
temperature loop 1 : 92.83
temperature loop 2 : 94.98
temperature loop 2 : 79.51
temperature loop 2 : 85.42
temperature loop 3 : 30.01
temperature loop 3 : 32.29
temperature loop 3 : 19
pressure loop D2 : 29.7276
pressure loop H2 : 31.8639