• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name LeRose

    Log entry time 16:30:06 on May10,2004

    Entry number 121395

    keyword=Shift Summary

    Production Running Be
    9:25 MCC says beam off until about 11:00 for scheduled injector work

    Somewhere in here there was a RICH trip that didn't trigger the alarm handler. Run 3449 is at least partially bad and run 3450 is all bad.

    10:10 RICH tripped while beam was off
    10:54 Beam is back
    ~11:30 fire alarm forces us out of the counting house (~15 minutes)
    12:53 RICH Trip
    14:28 RICH Trip
    15:41 "Vacuum Event" forces beam off

    runs
    3447 07:46-08:22 Be Production
    3448 08:23-08:45 Be Production
    3449 08:47-09:12 Be Production, RICH tripped but got no alarm
    3450 09:12-09:25 Be Production, ended because beam off

    3451 10:55-11:08 Be Production
    3452 11:10-11:40 Be Production
    3453 11:41-12:11 Be Production
    3454 12:13-12:23 Be Production, RICH Trip
    3455 12:28-13:01 Be Production
    3456 13:02-13:30 Be Production
    3457 13:32-14:14 Be Production
    3458 14:15-14:28 Be Production, RICH Trip
    3459 14:34-15:01 Be Production
    3460 15:02-15:41 Be Production Vacuum Event ends run