Main INDEX
Monthly INDEX
PREV
NEXT
User name LeRose
Log entry time 16:30:06 on May10,2004
Entry number 121395
keyword=Shift Summary
Production Running Be
9:25 MCC says beam off until about 11:00 for scheduled injector work
Somewhere in here there was a RICH trip that didn't trigger the alarm handler. Run 3449 is at least partially bad and run 3450 is all bad.
10:10 RICH tripped while beam was off
10:54 Beam is back
~11:30 fire alarm forces us out of the counting house (~15 minutes)
12:53 RICH Trip
14:28 RICH Trip
15:41 "Vacuum Event" forces beam off
runs
3447 07:46-08:22 Be Production
3448 08:23-08:45 Be Production
3449 08:47-09:12 Be Production, RICH tripped but got no alarm
3450 09:12-09:25 Be Production, ended because beam off
3451 10:55-11:08 Be Production
3452 11:10-11:40 Be Production
3453 11:41-12:11 Be Production
3454 12:13-12:23 Be Production, RICH Trip
3455 12:28-13:01 Be Production
3456 13:02-13:30 Be Production
3457 13:32-14:14 Be Production
3458 14:15-14:28 Be Production, RICH Trip
3459 14:34-15:01 Be Production
3460 15:02-15:41 Be Production Vacuum Event ends run