User name apar
Log entry time 05:56:45 on May 17, 2004
Entry number 122027
keyword=End_of_Parity_Run_1582__CODA_Config=GDH
End-of-Parity-run EPICS data for Run Number 1582 at Mon May 17 05:56:40 EDT 2004
CODA Configuration: GDH
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 2.49577
Wien BDL : 65.715
Wien field : 1.5373
Laser attenuation Hall A : 176
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 5600
IA Cell Setpoint Hall A : 7.85429
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.35
Gun2: PC (PITA) NEG : 7.5
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
LUMI HV - Ch 0 : -572.7
LUMI HV - Ch 1 : -751
LUMI HV - Ch 2 : -615.8
LUMI HV - Ch 3 : -575.6
LUMI HV - Ch 4 : -602.2
LUMI HV - Ch 5 : -511.6
LUMI HV - Ch 6 : -590.6
LUMI HV - Ch 7 : -517.7
LUMI HV - Ch 8 : -1.1
LUMI HV - Ch 9 : -3.3
LUMI HV - Ch 10 : -18.3
LUMI HV - Ch 11 : -13.1
Left Arm arm angle : 12.321
Right Arm arm angle : 0
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : 0
Left septum set current : 143.5
Left septum current readback : 143
Left septum upper coil T : 6.3
Left septum lower coil T : 6.5
Left septum yoke T : 4.9
Left septum bore shield T : 80.85
Left Arm Q1 power supply current : 930.77
Left Arm Q1 momentum : 1.54991
Left Arm Q1 gauss meter : -0.07854
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 672.44
Left Arm Q2 momentum : 1.54958
Left Arm Q2 gauss meter : 0.3549
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 520.659
Left Arm D1 momentum : 1.54994
Left Arm D1 NMR : 0.573632
Left Arm Q3 power supply current : 725.792
Left Arm Q3 momentum : 1.54988
Left Arm Q3 gauss meter : -0.3631
Left Arm Q3 power supply polarity : disabled
Right septum set current : 143.5
Right septum current readback : 143.5
Right septum upper coil T : 7.05
Right septum lower coil T : 6.6
Right septum yoke T : 5.7
Right septum bore shield T : 11.75
Right Arm Q1 power supply current : 926.658
Right Arm Q1 momentum : 1.55005
Right Arm Q1 gauss meter : -0.023087
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 672.642
Right Arm Q2 momentum : 1.55004
Right Arm Q2 gauss meter : 0.3537
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 532.927
Right Arm D1 momentum : 1.55
Right Arm D1 NMR : 0.575186
Right Arm Q3 power supply current : 725.889
Right Arm Q3 momentum : 1.55008
Right Arm Q3 gauss meter : 0.3258
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 0.585938
Left Arm Bottom VDC Current : 0.585938
Right Arm Top VDC Current : -0.78125
Right Arm Bottom VDC Current : -0.732422
Left Arm Top VDC voltage : 0.012207
Left Arm Bottom VDC voltage : 0.0107422
Right Arm Top VDC voltage : -0.00537109
Right Arm Bottom VDC voltage : -0.00585938
Average current of the two cavities : 39.3122
Current on Unser monitor : 36.2043
Current on Upstream bcm : 40.0915
Current on Downstream bcm : 38.5329
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 42.7454
Tiefenbach Hall A energy : 1535.44
Tiefenbach Hall C energy : 3029.5
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 1536.96
MBSY3c Hall C Beam energy : 3037.97
MBSY1c magnet current (amp) : 63.8565
MBSY1c Bdl : 383550
IPM1C12.XPOS : 1.42784
IPM1C12.YPOS : -0.0692083
IPM1H04A.XPOS : -0.375607
IPM1H04A.YPOS : -0.00419706
IPM1H04B.XPOS : -0.0570474
IPM1H04B.YPOS : -0.0407557
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0571289
Left LVDT HPM : 3.431e+19
Left LVDT VPM : -127380
HacL_HPE1313A:0_Ch58 : -0.178711
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.0419922
HacL_alignROLL : 0.380352
HacL_alignPITCH : -0.104889
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.321
Right Arm Collimator : -0.000146484
Right LVDT HPM : 3288
Right LVDT VPM : 3864
HacR_HPE1313A:0_Ch58 : -0.548828
HacR_HPE1313A:0_Ch55 : 21.6309
HacR_HPE1313A:0_Ch54 : -0.895996
HacR_alignROLL : 0
HacR_alignPITCH : 0
HacR_alignHPT : 0
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0
Arc OTR x-position : 0.538722
Arc OTR y-position : -0.986672
Arc OTR x-width : 0.29973
Arc OTR y-width : 0.298506
Arc OTR data valid flag : No
Arc OTR In/Out : MaxPix is Bad
fan frequency loop 1 : 40
fan frequency loop 2 : 0
fan frequency loop 3 : 40.5
Encoder position : 3303555
temperature loop 1 : 14.33
temperature loop 1 : 14.43
temperature loop 1 : 18.69
temperature loop 2 : 58.93
temperature loop 2 : 16.47
temperature loop 2 : 16.71
temperature loop 3 : 29.75
temperature loop 3 : 31.98
temperature loop 3 : 19.68
pressure loop D2 : 37.5143
pressure loop H2 : 37.6822