    User name apar

    Log entry time 23:05:16 on May 26, 2004

    Entry number 123232

    keyword=End_of_Parity_Run_1791__CODA_Config=happex2
    ************************************************
     Run Number: 1791
     End of Run Comment:
    
    Run_type=other,beam_energy=5.000,beam_polarization=99.93,beam_raster=on,comment_text=phase trombone test PT=(30,30),leftarm_p=2.49,leftarm_theta=6,parity_feedback=off,parity_ihwp=out,rightarm_p=2.50,rightarm_theta=6,target_fanspeed=59.5,target_type=15cm LH2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1791 at Wed May 26 23:05:10 EDT 2004
    CODA Configuration: happex2
    
    # Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
    
    Wien angle                               : 15.9458
    Wien BDL                                 : 368.58
    Wien field                               : 10.527
    Laser attenuation Hall A                 : 200
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 2500
    IA Cell Setpoint  Hall A                 : 5
    PZT X Setpoint  Hall A                   : 5
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 5
    Gun2: PC (PITA) NEG                      : 5
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Pair
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Pair
    G0 Helicity Random/Toggle Read           : Random
    Parity DAQ Feedback Control(1=on)        : 0
    LUMI HV - Ch  0                          : -600.2
    LUMI HV - Ch  1                          : -600.6
    LUMI HV - Ch  2                          : -435.4
    LUMI HV - Ch  3                          : -499.8
    LUMI HV - Ch  4                          : -721.9
    LUMI HV - Ch  5                          : -640.8
    LUMI HV - Ch  6                          : -561.6
    LUMI HV - Ch  7                          : -621.5
    LUMI HV - Ch  8                          : -1.1
    LUMI HV - Ch  9                          : -3.3
    LUMI HV - Ch  10                         : -18.3
    LUMI HV - Ch  11                         : -13.1
    Left Arm arm angle                       : 12.321
    Right Arm arm angle                      : 12.697
    Left Arm arm mispointing (HPT)           : -0
    Right Arm arm mispointing (HPT)          : -0
    Left septum set current                  : 178.68
    Left septum current readback             : 178
    Left septum upper coil T                 : 6.35
    Left septum lower coil T                 : 6.6
    Left septum yoke T                       : 4.95
    Left septum bore shield  T               : 80.55
    Left Arm Q1 power supply current         : 1158.92
    Left Arm Q1 momentum                     : 1.92994
    Left Arm Q1 gauss meter                  : 0.09862
    Left Arm Q1 power supply polarity        : 0
    Left Arm Q2 power supply current         : 837.452
    Left Arm Q2 momentum                     : 1.92984
    Left Arm Q2 gauss meter                  : -0.4411
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : 651.993
    Left Arm D1 momentum                     : 1.92999
    Left Arm D1 NMR                          : 0.71418
    Left Arm Q3 power supply current         : 903.779
    Left Arm Q3 momentum                     : 1.92996
    Left Arm Q3 gauss meter                  : 0.4521
    Left Arm Q3 power supply polarity        : enabled
    Right septum set current                 : 183.31
    Right septum current readback            : 183
    Right septum upper coil T                : 7.2
    Right septum lower coil T                : 6.8
    Right septum yoke T                      : 5.85
    Right septum bore shield  T              : 11.75
    Right Arm Q1 power supply current        : 1183.7
    Right Arm Q1 momentum                    : 1.98013
    Right Arm Q1 gauss meter                 : -0.0294
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 859.022
    Right Arm Q2 momentum                    : 1.97954
    Right Arm Q2 gauss meter                 : 0.4516
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 687.644
    Right Arm D1 momentum                    : 1.98
    Right Arm D1 NMR                         : 0.734753
    Right Arm Q3 power supply current        : 927.225
    Right Arm Q3 momentum                    : 1.98002
    Right Arm Q3 gauss meter                 : 0.4161
    Right Arm Q3 power supply polarity       : disabled
    Left Arm Top VDC Current                 : -1.46484
    Left Arm Bottom VDC Current              : 2.39258
    Right Arm Top VDC Current                : -0.244141
    Right Arm Bottom VDC Current             : -0.146484
    Left Arm Top VDC voltage                 : 3.98926
    Left Arm Bottom VDC voltage              : 3.99854
    Right Arm Top VDC voltage                : 4.00244
    Right Arm Bottom VDC voltage             : 3.99707
    Average current of the two cavities      : 0.0279922
    Current on Unser monitor                 : -4.55302
    Current on Upstream bcm                  : 0.0197407
    Current on Downstream bcm                : 0.0362436
    Upstream Cavity Coefficient              : 76.7
    Downstream Cavity Coefficient            : 78.9
    Current on IBC0L02 (source)              : 0.00143715
    Tiefenbach Hall A energy                 : 5009.28
    Tiefenbach Hall C energy                 : 5009.4
    Delta(E)/E width (MV_AI_DXWID)           : 3.66172
    MBSY1c Hall A Beam energy                : 5019.85
    MBSY3c Hall C Beam energy                : 5024.98
    MBSY1c magnet current (amp)              : 209.538
    MBSY1c Bdl                               : 1.25271e+06
    IPM1C12.XPOS                             : -0.00135303
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpmA                     : -0.63
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    Survey Y offset bpmB                     : -1
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.057373
    Left LVDT HPM                            : 3.441e+19
    Left LVDT VPM                            : -127380
    HacL_HPE1313A:0_Ch58                     : -0.178223
    HacL_HPE1313A:0_Ch55                     : 23.1445
    HacL_HPE1313A:0_Ch54                     : 0.0424805
    HacL_alignROLL                           : 0.381281
    HacL_alignPITCH                          : -0.105325
    HacL_alignHPT                            : -0
    Left Arm Angle Floor Angle               : 12.5
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : 12.321
    Right Arm Collimator                     : -0.000488281
    Right LVDT HPM                           : 3288
    Right LVDT VPM                           : 3866
    HacR_HPE1313A:0_Ch58                     : -0.54834
    HacR_HPE1313A:0_Ch55                     : 21.6797
    HacR_HPE1313A:0_Ch54                     : -0.898438
    HacR_alignROLL                           : -0.419524
    HacR_alignPITCH                          : -0.00629273
    HacR_alignHPT                            : -0
    Right Arm Angle Floor Angle              : 12.5
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 12.697
    Arc OTR  x-position                      : 0.981431
    Arc OTR  y-position                      : -1.71992
    Arc OTR  x-width                         : 3.13123
    Arc OTR  y-width                         : 1.4237
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : OTR is Out
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 60
    Encoder position                         : 15890561
    temperature loop 1                       : 93.8
    temperature loop 1                       : 99.99
    temperature loop 1                       : 92.83
    temperature loop 2                       : 94.98
    temperature loop 2                       : 84.87
    temperature loop 2                       : 92.16
    temperature loop 3                       : 30.05
    temperature loop 3                       : 32.34
    temperature loop 3                       : 19
    pressure loop D2                         : 26.3061
    pressure loop H2                         : 39.9069