Main INDEX
Monthly INDEX
PREV
NEXT
User name Bob & Bodo
Log entry time 11:17:21 on May27,2004
Entry number 123337
keyword=New definition of T7 !!
Work done by Bob Michaels and Bodo Reitz
Per Bogdan's request, T7 now requires the R-arm Cerenkov ("or" of
10 PMTs). The Cerenkov-or is passed through a NIM discriminator
at 100 mV. I don't know how many p.e. that is, but it looked
very low on the scale of scope signals. This signal is made 160 nsec
wide and after suitable delay arrives 70 nsec before T1 at the input
to the coincidence unit that makes T7. This coinc. unit is set
for triple coinc. To reverse this modification, one would simply
unplug the Cerenkov-or and return to dual-coinc (i.e. T1.and.T6).
T7 = T1.and.T6.and.R-arm-Cerenkov