keyword=Trigger Efficiency
Bob suggested investigating the new T7 efficiency, which has been updated to reduce left-arm pions (Aerogel) and enhance right-arm electrons (Gas Cerenkov).
The number of events passing the following software cuts (chosen to recreate T7 types) was found to be 21,678:
abs(ctime)<6
R.cer.asum_c>500
L.a1.asum_c<100
The number of those events which were actually labeled T7 was 13,127, corresponding to a trigger efficiency of around 61%.
If, in addition, a cut was placed to reduce the discrepancy observed at low values of L.a1.asum_c (>2), the efficiency was found to be around 88%.