Main INDEX
Monthly INDEX
PREV
NEXT
User name LeRose
Log entry time 16:02:44 on May31,2004
Entry number 124188
keyword=Shift Summary
Program is continue with Kin7 all day
0841 Q2 trips on low He level. Level comes back on its own. Q2 back and running by 0909. See halogs 124122 and 124124.
~0950 lost epics display of Lecroy HV. After verifying that HV was still on ran without the display while we figured out how to reboot iocha22. See halogs 124137, 124144, and 124147.Time gaps between runs 1549-1551 due to attempts to restore iocha22.
1320 diffuser waterflow fault! Called for controlled access to reset.
1345 out of access flow interlock cleared
1544 ended at 0814 1M kin7
1545 0814-0835 1.0M kin7
1546 0835-0842 0.3M kin7 Ended for Q2 trip
1547 0909-0929 1.0M kin7
1548 0929-0950 1.0M kin7
1549 0950-0953 Junk HV problem
1550 0958-1020 1.0M kin7
1551 1026-1047 1.0M kin7
1552 1047-1109 1.0M kin7
1553 1116-1138 1.0M kin7
1554 1138-1203 1.0M kin7
1555 1203-1223 1.0M kin7
1556 1224-1245 1.0M kin7
1557 1245-1309 1.0M kin7
1558 1309-1325 0.6M kin7 stopped because of dump diffuser waterflow trip
1559 1355-1416 1.0M kin7
1560 1416-1437 1.0M kin7
1561 1437-1459 1.0M kin7
1562 1459-1531 1.0M kin7
1563 1531-1553 1.0M kin7
1564 1553- Still going at shift end