User name apar
Log entry time 07:36:56 on June 1, 2004
Entry number 124304
keyword=Start_Parity_Run_1862__CODA_Config=happex2_Run_type=other,beam_energy=5.000,beam_polarization=0,beam_raster=on,comment_text=15 uA, charge feedback, 2 minute,leftarm_p=1.93,leftarm_theta=6,parity_feedback=on,parity_ihwp=out,rightarm_p=1.98,rightarm_theta=6,target_fanspeed=59.5,target_type=15cm LH2
Beginning-of-Parity-run EPICS data for Run Number 1862 at Tue Jun 1 07:36:42 EDT 2004
CODA Configuration: happex2
# Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 15.9458
Wien BDL : 368.58
Wien field : 10.527
Laser attenuation Hall A : 178
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 2250
IA Cell Setpoint Hall A : 5.21
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5
Gun2: PC (PITA) NEG : 5
Gun3: PC (PITA) POS : 4.884
Gun3: PC (PITA) NEG : 6.05
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
LUMI HV - Ch 0 : -600.2
LUMI HV - Ch 1 : -600.6
LUMI HV - Ch 2 : -435.4
LUMI HV - Ch 3 : -499.8
LUMI HV - Ch 4 : -721.9
LUMI HV - Ch 5 : -640.8
LUMI HV - Ch 6 : -561.6
LUMI HV - Ch 7 : -621.5
LUMI HV - Ch 8 : -1.1
LUMI HV - Ch 9 : -3.3
LUMI HV - Ch 10 : -18.3
LUMI HV - Ch 11 : -13.1
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left septum set current : 174.89
Left septum current readback : 175.25
Left septum upper coil T : 6.6
Left septum lower coil T : 6.85
Left septum yoke T : 5
Left septum bore shield T : 80.5
Left Arm Q1 power supply current : 1134.89
Left Arm Q1 momentum : 1.89
Left Arm Q1 gauss meter : 0.09659
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 820.269
Left Arm Q2 momentum : 1.89007
Left Arm Q2 gauss meter : -0.4321
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 637.626
Left Arm D1 momentum : 1.89
Left Arm D1 NMR : 0.699391
Left Arm Q3 power supply current : 885.113
Left Arm Q3 momentum : 1.8901
Left Arm Q3 gauss meter : 0.4429
Left Arm Q3 power supply polarity : enabled
Right septum set current : 171.27
Right septum current readback : 171.25
Right septum upper coil T : 7.55
Right septum lower coil T : 7.2
Right septum yoke T : 5.95
Right septum bore shield T : 11.9
Right Arm Q1 power supply current : 1105.89
Right Arm Q1 momentum : 1.84996
Right Arm Q1 gauss meter : -0.02747
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 802.816
Right Arm Q2 momentum : 1.85002
Right Arm Q2 gauss meter : 0.4219
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 639.801
Right Arm D1 momentum : 1.85
Right Arm D1 NMR : 0.686512
Right Arm Q3 power supply current : 866.343
Right Arm Q3 momentum : 1.85001
Right Arm Q3 gauss meter : 0.3888
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -13.5254
Left Arm Bottom VDC Current : -13.8184
Right Arm Top VDC Current : -12.5977
Right Arm Bottom VDC Current : -17.6758
Left Arm Top VDC voltage : 3.99316
Left Arm Bottom VDC voltage : 3.99902
Right Arm Top VDC voltage : 3.99609
Right Arm Bottom VDC voltage : 3.99463
Average current of the two cavities : 15.7696
Current on Unser monitor : 12.8197
Current on Upstream bcm : 16.1892
Current on Downstream bcm : 15.3501
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 16.4569
Tiefenbach Hall A energy : 5009.28
Tiefenbach Hall C energy : 5009.4
Delta(E)/E width (MV_AI_DXWID) : 2.81252
MBSY1c Hall A Beam energy : 5019.85
MBSY3c Hall C Beam energy : 5024.98
MBSY1c magnet current (amp) : 209.538
MBSY1c Bdl : 1.25271e+06
IPM1C12.XPOS : -0.0228428
IPM1C12.YPOS : -0.00887768
IPM1H04A.XPOS : 2.1613
IPM1H04A.YPOS : 0.0122863
IPM1H04B.XPOS : -1.80869
IPM1H04B.YPOS : 0.0457051
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0577637
Left LVDT HPM : 3.441e+19
Left LVDT VPM : -127378
HacL_HPE1313A:0_Ch58 : -0.177734
HacL_HPE1313A:0_Ch55 : 23.2422
HacL_HPE1313A:0_Ch54 : 0.043457
HacL_alignROLL : 0.383217
HacL_alignPITCH : -0.105399
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.321
Right Arm Collimator : -0.00078125
Right LVDT HPM : 3288
Right LVDT VPM : 3866
HacR_HPE1313A:0_Ch58 : -0.545898
HacR_HPE1313A:0_Ch55 : 21.875
HacR_HPE1313A:0_Ch54 : -0.89502
HacR_alignROLL : -0.415851
HacR_alignPITCH : -0.00924984
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Arc OTR x-position : 0.262453
Arc OTR y-position : 0.126291
Arc OTR x-width : 0.134713
Arc OTR y-width : 0.09232
Arc OTR data valid flag : Yes
Arc OTR In/Out :
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 72
Encoder position : 15890561
temperature loop 1-1 : 93.8
temperature loop 1-2 : 99.99
temperature loop 1-3 : 92.83
temperature loop 2-1 : 94.89
temperature loop 2-2 : 84.06
temperature loop 2-3 : 91.52
temperature loop 3-1 : 30.01
temperature loop 3-2 : 32.29
temperature loop 3-3 : 19
pressure loop D2 : 26.5123
pressure loop H2 : 40.5234