User name apar
Log entry time 22:44:47 on June 1, 2004
Entry number 124350
keyword=Start_Parity_Run_1872__CODA_Config=happex2_Run_type=other,beam_energy=5.000,beam_polarization=0,beam_raster=off,comment_text=Calibration of Cavity Monitors,leftarm_p=1.93,leftarm_theta=6,parity_feedback=on,parity_ihwp=out,rightarm_p=1.98,rightarm_theta=6,target_fanspeed=59.5,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 1872 at Tue Jun 1 22:44:42 EDT 2004
CODA Configuration: happex2
# Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 15.9458
Wien BDL : 368.53
Wien field : 10.527
Laser attenuation Hall A : 80
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 2250
IA Cell Setpoint Hall A : 4.98
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5
Gun2: PC (PITA) NEG : 5
Gun3: PC (PITA) POS : 4.884
Gun3: PC (PITA) NEG : 6.05
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
LUMI HV - Ch 0 : -600.2
LUMI HV - Ch 1 : -600.6
LUMI HV - Ch 2 : -435.4
LUMI HV - Ch 3 : -499.8
LUMI HV - Ch 4 : -721.9
LUMI HV - Ch 5 : -640.8
LUMI HV - Ch 6 : -561.6
LUMI HV - Ch 7 : -621.5
LUMI HV - Ch 8 : -1.1
LUMI HV - Ch 9 : -3.3
LUMI HV - Ch 10 : -18.3
LUMI HV - Ch 11 : -13.1
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left septum set current : 0
Left septum current readback : 0
Left septum upper coil T : 6.3
Left septum lower coil T : 6.45
Left septum yoke T : 4.85
Left septum bore shield T : 80.8
Left Arm Q1 power supply current : 1135
Left Arm Q1 momentum : 1.89009
Left Arm Q1 gauss meter : 0.09649
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 820.148
Left Arm Q2 momentum : 1.88996
Left Arm Q2 gauss meter : -0.432
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 640.992
Left Arm D1 momentum : 1.89
Left Arm D1 NMR : 0.699391
Left Arm Q3 power supply current : 885.018
Left Arm Q3 momentum : 1.88989
Left Arm Q3 gauss meter : 0.4429
Left Arm Q3 power supply polarity : enabled
Right septum set current : 0
Right septum current readback : 104.75
Right septum upper coil T : 7.1
Right septum lower coil T : 6.7
Right septum yoke T : 5.7
Right septum bore shield T : 12.55
Right Arm Q1 power supply current : 1106
Right Arm Q1 momentum : 1.85014
Right Arm Q1 gauss meter : -0.027504
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 803.031
Right Arm Q2 momentum : 1.85051
Right Arm Q2 gauss meter : 0.4211
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 10.0856
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.706544
Right Arm Q3 power supply current : 866.31
Right Arm Q3 momentum : 1.84994
Right Arm Q3 gauss meter : 0.3889
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -1.80664
Left Arm Bottom VDC Current : 0.78125
Right Arm Top VDC Current : 0.976562
Right Arm Bottom VDC Current : -2.05078
Left Arm Top VDC voltage : 3.9917
Left Arm Bottom VDC voltage : 4
Right Arm Top VDC voltage : 3.99707
Right Arm Bottom VDC voltage : 4.00146
Average current of the two cavities : 0.0278679
Current on Unser monitor : -3.10954
Current on Upstream bcm : 0.0246068
Current on Downstream bcm : 0.031129
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143715
Tiefenbach Hall A energy : 5009.29
Tiefenbach Hall C energy : 5009.41
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 5019.85
MBSY3c Hall C Beam energy : 5024.98
MBSY1c magnet current (amp) : 209.538
MBSY1c Bdl : 1.25271e+06
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0575195
Left LVDT HPM : 3.441e+19
Left LVDT VPM : -127379
HacL_HPE1313A:0_Ch58 : -0.177734
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : 0.0419922
HacL_alignROLL : 0.381359
HacL_alignPITCH : -0.105835
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.321
Right Arm Collimator : -0.000683594
Right LVDT HPM : 3288
Right LVDT VPM : 3869
HacR_HPE1313A:0_Ch58 : -0.54834
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -0.895996
HacR_alignROLL : -0.416892
HacR_alignPITCH : -0.00694004
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Arc OTR x-position : 0.258127
Arc OTR y-position : 0.139898
Arc OTR x-width : 0.436926
Arc OTR y-width : 0.170426
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 72
Encoder position : 9075343
temperature loop 1-1 : 93.8
temperature loop 1-2 : 99.99
temperature loop 1-3 : 92.83
temperature loop 2-1 : 94.98
temperature loop 2-2 : 84.88
temperature loop 2-3 : 92.21
temperature loop 3-1 : 30.06
temperature loop 3-2 : 32.35
temperature loop 3-3 : 19
pressure loop D2 : 26.7588
pressure loop H2 : 40.6683