User name apar
Log entry time 22:58:35 on June 1, 2004
Entry number 124353
keyword=Start_Parity_Run_1873__CODA_Config=happex2_Run_type=other,beam_energy=5.000,beam_polarization=0,beam_raster=off,comment_text=Calibration of Cavity Monitors, with dithering. Energy and Position lock off,leftarm_p=1.93,leftarm_theta=6,parity_feedback=on,parity_ihwp=out,rightarm_p=1.98,rightarm_theta=6,target_fanspeed=59.5,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 1873 at Tue Jun 1 22:58:30 EDT 2004
CODA Configuration: happex2
# Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 15.9458
Wien BDL : 368.53
Wien field : 10.527
Laser attenuation Hall A : 108
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 2250
IA Cell Setpoint Hall A : 4.98
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5
Gun2: PC (PITA) NEG : 5
Gun3: PC (PITA) POS : 4.884
Gun3: PC (PITA) NEG : 6.05
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
LUMI HV - Ch 0 : -600.2
LUMI HV - Ch 1 : -600.6
LUMI HV - Ch 2 : -435.4
LUMI HV - Ch 3 : -499.8
LUMI HV - Ch 4 : -721.9
LUMI HV - Ch 5 : -640.8
LUMI HV - Ch 6 : -561.6
LUMI HV - Ch 7 : -621.5
LUMI HV - Ch 8 : -1.1
LUMI HV - Ch 9 : -3.3
LUMI HV - Ch 10 : -18.3
LUMI HV - Ch 11 : -13.1
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left septum set current : 0
Left septum current readback : -2
Left septum upper coil T : 6.3
Left septum lower coil T : 6.45
Left septum yoke T : 4.85
Left septum bore shield T : 80.8
Left Arm Q1 power supply current : 1135
Left Arm Q1 momentum : 1.89009
Left Arm Q1 gauss meter : 0.09648
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 820.019
Left Arm Q2 momentum : 1.88966
Left Arm Q2 gauss meter : -0.432
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 640.98
Left Arm D1 momentum : 1.88998
Left Arm D1 NMR : 0.699383
Left Arm Q3 power supply current : 885.055
Left Arm Q3 momentum : 1.88997
Left Arm Q3 gauss meter : 0.4429
Left Arm Q3 power supply polarity : enabled
Right septum set current : 0
Right septum current readback : 90.25
Right septum upper coil T : 7.05
Right septum lower coil T : 6.6
Right septum yoke T : 5.65
Right septum bore shield T : 11.9
Right Arm Q1 power supply current : 1105.94
Right Arm Q1 momentum : 1.85014
Right Arm Q1 gauss meter : -0.027462
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 802.838
Right Arm Q2 momentum : 1.85007
Right Arm Q2 gauss meter : 0.4211
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 8.80572
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.703484
Right Arm Q3 power supply current : 866.175
Right Arm Q3 momentum : 1.84965
Right Arm Q3 gauss meter : 0.3888
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 0.0976562
Left Arm Bottom VDC Current : 3.41797
Right Arm Top VDC Current : -2.58789
Right Arm Bottom VDC Current : -1.9043
Left Arm Top VDC voltage : 3.97998
Left Arm Bottom VDC voltage : 4.00195
Right Arm Top VDC voltage : 4.00049
Right Arm Bottom VDC voltage : 4.00146
Average current of the two cavities : 4.65571
Current on Unser monitor : -0.184016
Current on Upstream bcm : 4.81325
Current on Downstream bcm : 4.49817
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 4.98009
Tiefenbach Hall A energy : 5009.18
Tiefenbach Hall C energy : 5009.41
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 5019.85
MBSY3c Hall C Beam energy : 5024.98
MBSY1c magnet current (amp) : 209.538
MBSY1c Bdl : 1.25271e+06
IPM1C12.XPOS : 0.0954077
IPM1C12.YPOS : 0.0691988
IPM1H04A.XPOS : 0.322549
IPM1H04A.YPOS : -0.542205
IPM1H04B.XPOS : 0.0178193
IPM1H04B.YPOS : -0.340522
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0570313
Left LVDT HPM : 3.441e+19
Left LVDT VPM : -127379
HacL_HPE1313A:0_Ch58 : -0.177734
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.0429688
HacL_alignROLL : 0.381746
HacL_alignPITCH : -0.105762
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.321
Right Arm Collimator : -0.000488281
Right LVDT HPM : 3288
Right LVDT VPM : 3867
HacR_HPE1313A:0_Ch58 : -0.54834
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -0.896484
HacR_alignROLL : -0.417878
HacR_alignPITCH : -0.00694004
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Arc OTR x-position : 0.254576
Arc OTR y-position : 0.135485
Arc OTR x-width : 0.433887
Arc OTR y-width : 0.171235
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 72
Encoder position : 9075343
temperature loop 1-1 : 93.8
temperature loop 1-2 : 99.99
temperature loop 1-3 : 92.83
temperature loop 2-1 : 94.98
temperature loop 2-2 : 84.63
temperature loop 2-3 : 91.8
temperature loop 3-1 : 30.06
temperature loop 3-2 : 32.35
temperature loop 3-3 : 19
pressure loop D2 : 26.5772
pressure loop H2 : 40.7965