Log entry time 01:31:28 on June 2, 2004
Entry number 124379
keyword=End_of_Parity_Run_1878__CODA_Config=happex2
************************************************
Run Number: 1878
End of Run Comment:
Run_type=other,beam_energy=5.000,beam_polarization=0,beam_raster=on,comment_text=Beam Modulation, spot++ 4x4, 20uA,leftarm_p=1.93,leftarm_theta=6,parity_feedback=on,parity_ihwp=out,rightarm_p=1.98,rightarm_theta=6,target_fanspeed=59.5,target_type=15cm LH2
************************************************
End-of-Parity-run EPICS data for Run Number 1878 at Wed Jun 2 01:31:23 EDT 2004
CODA Configuration: happex2
# Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 15.9458
Wien BDL : 368.53
Wien field : 10.527
Laser attenuation Hall A : 209
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 2250
IA Cell Setpoint Hall A : 4.98
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5
Gun2: PC (PITA) NEG : 5
Gun3: PC (PITA) POS : 4.884
Gun3: PC (PITA) NEG : 6.05
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
LUMI HV - Ch 0 : -500.2
LUMI HV - Ch 1 : -651
LUMI HV - Ch 2 : -570.3
LUMI HV - Ch 3 : -499.8
LUMI HV - Ch 4 : -591.5
LUMI HV - Ch 5 : -520.7
LUMI HV - Ch 6 : -582.2
LUMI HV - Ch 7 : -512.3
LUMI HV - Ch 8 : -1.9
LUMI HV - Ch 9 : -3.3
LUMI HV - Ch 10 : -19
LUMI HV - Ch 11 : -13.1
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left septum set current : 0
Left septum current readback : -1.5
Left septum upper coil T : 6.55
Left septum lower coil T : 6.7
Left septum yoke T : 4.95
Left septum bore shield T : 80.8
Left Arm Q1 power supply current : 1134.94
Left Arm Q1 momentum : 1.89
Left Arm Q1 gauss meter : 0.09649
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 820.196
Left Arm Q2 momentum : 1.89007
Left Arm Q2 gauss meter : -0.432
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 640.99
Left Arm D1 momentum : 1.89
Left Arm D1 NMR : 0.699391
Left Arm Q3 power supply current : 885.103
Left Arm Q3 momentum : 1.89007
Left Arm Q3 gauss meter : 0.4429
Left Arm Q3 power supply polarity : enabled
Right septum set current : 0
Right septum current readback : 0
Right septum upper coil T : 7.7
Right septum lower coil T : 7.3
Right septum yoke T : 5.8
Right septum bore shield T : 10.7
Right Arm Q1 power supply current : 1105.94
Right Arm Q1 momentum : 1.85005
Right Arm Q1 gauss meter : -0.027487
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 0.227643
Right Arm Q2 momentum : 0.000524583
Right Arm Q2 gauss meter : 0.000611
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 3.67805
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.836799
Right Arm Q3 power supply current : 866.237
Right Arm Q3 momentum : 1.84979
Right Arm Q3 gauss meter : 0.3889
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -2.14844
Left Arm Bottom VDC Current : 2.58789
Right Arm Top VDC Current : 1.41602
Right Arm Bottom VDC Current : -2.63672
Left Arm Top VDC voltage : 3.9917
Left Arm Bottom VDC voltage : 4
Right Arm Top VDC voltage : 4.00146
Right Arm Bottom VDC voltage : 4.00488
Average current of the two cavities : 18.8895
Current on Unser monitor : 14.5743
Current on Upstream bcm : 19.388
Current on Downstream bcm : 18.391
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 19.8839
Tiefenbach Hall A energy : 5009.3
Tiefenbach Hall C energy : 5009.41
Delta(E)/E width (MV_AI_DXWID) : 1.78053
MBSY1c Hall A Beam energy : 5019.85
MBSY3c Hall C Beam energy : 5024.98
MBSY1c magnet current (amp) : 209.538
MBSY1c Bdl : 1.25271e+06
IPM1C12.XPOS : -0.103148
IPM1C12.YPOS : -0.00732167
IPM1H04A.XPOS : 0.292475
IPM1H04A.YPOS : -0.147574
IPM1H04B.XPOS : -0.0463201
IPM1H04B.YPOS : 0.0498994
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0573242
Left LVDT HPM : 3.441e+19
Left LVDT VPM : -127378
HacL_HPE1313A:0_Ch58 : -0.177734
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : 0.0419922
HacL_alignROLL : 0.381359
HacL_alignPITCH : -0.105835
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.321
Right Arm Collimator : -0.000244141
Right LVDT HPM : 3288
Right LVDT VPM : 3868
HacR_HPE1313A:0_Ch58 : -0.547852
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -0.896484
HacR_alignROLL : -0.416456
HacR_alignPITCH : -0.00732255
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Arc OTR x-position : 0.0919552
Arc OTR y-position : 0.130026
Arc OTR x-width : 0.162324
Arc OTR y-width : 0.0984326
Arc OTR data valid flag : No
Arc OTR In/Out : MaxPix is Bad
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 72
Encoder position : 15890561
temperature loop 1-1 : 93.8
temperature loop 1-2 : 99.99
temperature loop 1-3 : 92.83
temperature loop 2-1 : 93.1
temperature loop 2-2 : 82.48
temperature loop 2-3 : 89.76
temperature loop 3-1 : 30.01
temperature loop 3-2 : 32.29
temperature loop 3-3 : 19
pressure loop D2 : 26.6446
pressure loop H2 : 40.7263