User name apar
Log entry time 20:19:39 on June 4, 2004
Entry number 124716
keyword=Start_Parity_Run_1884__CODA_Config=happex2_Run_type=other,beam_energy=5.000,beam_polarization=0,beam_raster=on,comment_text=Test of HAPPEX Feedback results in the end of run halog,leftarm_p=1.93,leftarm_theta=6,parity_feedback=on,parity_ihwp=out,rightarm_p=1.98,rightarm_theta=6,target_fanspeed=59.5,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 1884 at Fri Jun 4 20:19:34 EDT 2004
CODA Configuration: happex2
# Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 15.9458
Wien BDL : 368.53
Wien field : 10.527
Laser attenuation Hall A : 100
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 2250
IA Cell Setpoint Hall A : 5
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5
Gun2: PC (PITA) NEG : 5
Gun3: PC (PITA) POS : 4.884
Gun3: PC (PITA) NEG : 6.05
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
LUMI HV - Ch 0 : -0.4
LUMI HV - Ch 1 : -0.8
LUMI HV - Ch 2 : 0.5
LUMI HV - Ch 3 : 0.4
LUMI HV - Ch 4 : 0
LUMI HV - Ch 5 : -0
LUMI HV - Ch 6 : -0.3
LUMI HV - Ch 7 : 0
LUMI HV - Ch 8 : -0.3
LUMI HV - Ch 9 : -1
LUMI HV - Ch 10 : -0.8
LUMI HV - Ch 11 : -0.8
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left septum set current : 0
Left septum current readback : -2
Left septum upper coil T : 6.3
Left septum lower coil T : 6.5
Left septum yoke T : 4.85
Left septum bore shield T : 80.65
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter : 0.0002061
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.225427
Left Arm Q2 momentum : 0.000519477
Left Arm Q2 gauss meter : 0.0011341
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 0.0816845
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.440696
Left Arm Q3 power supply current : 2.09565
Left Arm Q3 momentum : 0.00447511
Left Arm Q3 gauss meter : -6.23e-05
Left Arm Q3 power supply polarity : disabled
Right septum set current : 0
Right septum current readback : 0
Right septum upper coil T : 7.45
Right septum lower coil T : 6.95
Right septum yoke T : 5.8
Right septum bore shield T : 11.25
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : -9.87e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 0.399871
Right Arm Q2 momentum : 0.000921469
Right Arm Q2 gauss meter : 0.0005903
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1.88695
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.379902
Right Arm Q3 power supply current : 0.106937
Right Arm Q3 momentum : 0.000228356
Right Arm Q3 gauss meter : 0.0002705
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 0.683594
Left Arm Bottom VDC Current : 0.683594
Right Arm Top VDC Current : -0.78125
Right Arm Bottom VDC Current : -0.732422
Left Arm Top VDC voltage : 0.0107422
Left Arm Bottom VDC voltage : 0.0112305
Right Arm Top VDC voltage : -0.00585938
Right Arm Bottom VDC voltage : -0.00537109
Average current of the two cavities : 0.0278514
Current on Unser monitor : -5.6543
Current on Upstream bcm : 0.0203487
Current on Downstream bcm : 0.0353541
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143715
Tiefenbach Hall A energy : 5009.29
Tiefenbach Hall C energy : 5009.41
Delta(E)/E width (MV_AI_DXWID) : 0.567217
MBSY1c Hall A Beam energy : 5019.85
MBSY3c Hall C Beam energy : 5024.98
MBSY1c magnet current (amp) : 5.08079e-06
MBSY1c Bdl : 1.25271e+06
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0576172
Left LVDT HPM : 3.441e+19
Left LVDT VPM : -127382
HacL_HPE1313A:0_Ch58 : -0.204102
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.0444336
HacL_alignROLL : 0.38314
HacL_alignPITCH : -0.0821892
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.321
Right Arm Collimator : -0.000244141
Right LVDT HPM : 3288
Right LVDT VPM : 3865
HacR_HPE1313A:0_Ch58 : -0.547852
HacR_HPE1313A:0_Ch55 : 21.875
HacR_HPE1313A:0_Ch54 : -0.898926
HacR_alignROLL : -0.418371
HacR_alignPITCH : -0.00783744
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Arc OTR x-position : 0.202243
Arc OTR y-position : 0.111167
Arc OTR x-width : 0.377729
Arc OTR y-width : 0.112419
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
Encoder position : 15890560
temperature loop 1-1 : 93.8
temperature loop 1-2 : 99.99
temperature loop 1-3 : 92.83
temperature loop 2-1 : 94.98
temperature loop 2-2 : 94.98
temperature loop 2-3 : 94.98
temperature loop 3-1 : 94.98
temperature loop 3-2 : 94.98
temperature loop 3-3 : 94.98
pressure loop D2 : 36.3839
pressure loop H2 : 45.9632