    User name apar

    Log entry time 21:43:18 on June 10, 2004

    Entry number 125272

    keyword=Start_Parity_Run_2014__CODA_Config=happex2_Run_type=other,beam_energy=2.983,beam_polarization=0,beam_raster=off,comment_text=Sync check,leftarm_p=2.9832,leftarm_theta=6,parity_feedback=off,parity_ihwp=out,rightarm_p=2.9832,rightarm_theta=6,target_fanspeed=59.5,target_type=Empty
    Beginning-of-Parity-run EPICS data for Run Number 2014 at Thu Jun 10 21:42:28 EDT 2004
    CODA Configuration: happex2
    
    # Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
    
    Wien angle                               : 15.9458
    Wien BDL                                 : 377.34
    Wien field                               : 10.527
    Laser attenuation Hall A                 : 70
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 750
    IA Cell Setpoint  Hall A                 : 5
    PZT X Setpoint  Hall A                   : 5
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 5
    Gun2: PC (PITA) NEG                      : 5
    Gun3: PC (PITA) POS                      : 4.05
    Gun3: PC (PITA) NEG                      : 7.743
    Pockels Cell Voltage POS                 : 2.61538
    Pockels Cell Voltage NEG                 : 2.74725
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Pair
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Pair
    G0 Helicity Random/Toggle Read           : Random
    Parity DAQ Feedback Control(1=on)        : 0
    LUMI HV - Ch  0                          : -600.2
    LUMI HV - Ch  1                          : -901.3
    LUMI HV - Ch  2                          : -700.7
    LUMI HV - Ch  3                          : -600.9
    LUMI HV - Ch  4                          : -726.4
    LUMI HV - Ch  5                          : -625.6
    LUMI HV - Ch  6                          : -676.9
    LUMI HV - Ch  7                          : -626.9
    LUMI HV - Ch  8                          : -10.3
    LUMI HV - Ch  9                          : -18.6
    LUMI HV - Ch  10                         : -19
    LUMI HV - Ch  11                         : -13.1
    HAPPEX Detector1 HV - Left Slot10 Ch9    : -2.2
    HAPPEX Detector2 HV - Left Slot10 Ch10   : -18.1
    HAPPEX Detector3 HV - RightB Slot10 Ch10 : -1.9
    HAPPEX Detector4 HV - RightB Slot10 Ch9  : -20.7
    Scanner Left HV - Left Slot10 Ch11       : -8.1
    Scanner Right HV - RightB Slot10 Ch11    : -10
    Left Arm arm angle                       : 12.321
    Right Arm arm angle                      : 12.697
    Left Arm arm mispointing (HPT)           : -0
    Right Arm arm mispointing (HPT)          : -0
    Left septum set current                  : 280.7
    Left septum current readback             : 279.75
    Left septum upper coil T                 : 6.05
    Left septum lower coil T                 : 6.2
    Left septum yoke T                       : 4.8
    Left septum bore shield  T               : 81.05
    Left Arm Q1 power supply current         : 1820.52
    Left Arm Q1 momentum                     : 3.0316
    Left Arm Q1 gauss meter                  : -0.15361
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1315.57
    Left Arm Q2 momentum                     : 3.03162
    Left Arm Q2 gauss meter                  : 0.6929
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1064.16
    Left Arm D1 momentum                     : 3.0315
    Left Arm D1 NMR                          : 1.12253
    Left Arm Q3 power supply current         : 1419.63
    Left Arm Q3 momentum                     : 3.03152
    Left Arm Q3 gauss meter                  : -0.71
    Left Arm Q3 power supply polarity        : disabled
    Right septum set current                 : 280.7
    Right septum current readback            : 280.25
    Right septum upper coil T                : 6.6
    Right septum lower coil T                : 6.35
    Right septum yoke T                      : 5.65
    Right septum bore shield  T              : 12.5
    Right Arm Q1 power supply current        : 1812.25
    Right Arm Q1 momentum                    : 3.03158
    Right Arm Q1 gauss meter                 : -0.04481
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1315.55
    Right Arm Q2 momentum                    : 3.03156
    Right Arm Q2 gauss meter                 : 0.6907
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1090.13
    Right Arm D1 momentum                    : 3.0315
    Right Arm D1 NMR                         : 1.12495
    Right Arm Q3 power supply current        : 1419.72
    Right Arm Q3 momentum                    : 3.03171
    Right Arm Q3 gauss meter                 : 0.6368
    Right Arm Q3 power supply polarity       : disabled
    Left Arm Top VDC Current                 : 0.634766
    Left Arm Bottom VDC Current              : 0.634766
    Right Arm Top VDC Current                : -0.78125
    Right Arm Bottom VDC Current             : -0.78125
    Left Arm Top VDC voltage                 : 0.0102539
    Left Arm Bottom VDC voltage              : 0.0102539
    Right Arm Top VDC voltage                : -0.00537109
    Right Arm Bottom VDC voltage             : -0.00537109
    Average current of the two cavities      : 0.0279581
    Current on Unser monitor                 : -6.02029
    Current on Upstream bcm                  : 0.0215595
    Current on Downstream bcm                : 0.0343566
    Upstream Cavity Coefficient              : 76.7
    Downstream Cavity Coefficient            : 78.9
    Current on IBC0L02 (source)              : 0.00143715
    Tiefenbach Hall A energy                 : 3028.47
    Tiefenbach Hall C energy                 : 5009.41
    Delta(E)/E width (MV_AI_DXWID)           : 8.82267
    MBSY1c Hall A Beam energy                : 3033.17
    MBSY3c Hall C Beam energy                : 5024.98
    MBSY1c magnet current (amp)              : 0.0377198
    MBSY1c Bdl                               : 756932
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpmA                     : -0.63
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    Survey Y offset bpmB                     : -1
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.0579102
    Left LVDT HPM                            : 3.441e+19
    Left LVDT VPM                            : -127376
    HacL_HPE1313A:0_Ch58                     : -0.177734
    HacL_HPE1313A:0_Ch55                     : 23.1934
    HacL_HPE1313A:0_Ch54                     : 0.0375977
    HacL_alignROLL                           : 0.376712
    HacL_alignPITCH                          : -0.104962
    HacL_alignHPT                            : -0
    Left Arm Angle Floor Angle               : 12.5
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : 12.321
    Right Arm Collimator                     : -0.000683594
    Right LVDT HPM                           : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: HacR_HPM_LVDT:VALr Accepted: hallasc25.jlab.org Rejected: iocha16.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 3288
    Right LVDT VPM                           : 3876
    HacR_HPE1313A:0_Ch58                     : -0.540527
    HacR_HPE1313A:0_Ch55                     : 22.0215
    HacR_HPE1313A:0_Ch54                     : -0.88916
    HacR_alignROLL                           : -0.409388
    HacR_alignPITCH                          : -0.0151495
    HacR_alignHPT                            : -0
    Right Arm Angle Floor Angle              : 12.5
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 12.697
    Arc OTR  x-position                      : 0.667836
    Arc OTR  y-position                      : 2.06308
    Arc OTR  x-width                         : 0.624636
    Arc OTR  y-width                         : 0.656386
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : OTR is Out
    fan frequency loop 1                     : 48
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    Encoder position                         : 1677968
    temperature loop 1-1                     : 6.6
    temperature loop 1-2                     : 6.64
    temperature loop 1-3                     : 7.13
    temperature loop 2-1                     : 94.98
    temperature loop 2-2                     : 94.98
    temperature loop 2-3                     : 94.98
    temperature loop 3-1                     : 94.98
    temperature loop 3-2                     : 94.98
    temperature loop 3-3                     : 94.98
    pressure loop D2                         : 26.1855
    pressure loop H2                         : 31.2947
    
    Parameters used for HAPPEX feedback
    anatype fdbk
    curmon bcm1
    feedback IA on 2 bcm1
    feedback PZT onc 20 bpm4b
    IAparam slope -149