    User name R. Michaels

    Log entry time 01:54:43 on June11,2004

    Entry number 125308

    This entry is a followup to: 125294

    keyword=funny amplitude dependence

    Fig 1 shows the momentum distribution for He4 target for S2
    trigger (top plot) and HAPPEX trig (middle plot). It was
    verified that this middle plot looks the same if instead of
    a trigger cut, I require the HAPPEX ADC > 500 (no surpise here).
    What is a little surprising is that if I cut on ADC > 1500 I
    get the bottom plot. Hmm.... we might be on the edge of
    something, but ... not sure.


    FIGURE 1