• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Holmstrom

    Log entry time 08:00:18 on June15,2004

    Entry number 125833

    keyword=Tuesday Owl Shift Log

    00:00 Shift Starts - Lisa is working on the PITA scan. 
    
    00:13 Lisa finished with PITA scan
    
    Scanner Comission Running:
    00:14 Run 2139 Started 
    00:35 Run 2139 Stopped (So that UMASS scanner crew could reset their program)
    00:36 Run 2140 Started
    00:53 Septum controls are lost
    00:59 Attempted Reboot Using Instructions from Last Shift
    01:05 Reboot succesful!
    01:10 Ended 2140 JUNK
    01:11 Run 2141 Junk
    01:18 Started Run 2142 - Testing Rate to see if Septi are good.
    01:28 ended Run 2142 (Things look good)
    01:29 Started Run 2143 - Finishing Scanner check out. 
    01:30 Called Hall B to give them 15 notice of dithering run.
    01:45 Ended Run 2143
    01:47 Start Run 2144  - Dithering Run
    01:57 Ended Run 2144
    02:00 Run 2145 Junk
    
    Production data:
    02:01 - 02:57       Run 2146
    03:00 - 03:56       Run 2147
    
    Dithering Run:
    Run 2148  -- Junk
    03:58 -  04:08      Run 2149
    
    Production data:
    Run 2150 Junk
    04:12 - 05:08       Run 2151
    05:09 - 05:48	    Run 2152  (We lost ROC26, stoped run early)
       Bryan fixed the problem by rebooting CODA
    05:56 - 06:12       Run 2153
    
    Dithering Run:
    Run  
    06:14 - 06:28       Run 2154
    
    Production data:
    06:29 - 07:03       Run 2155
    07:05 - 08:00       Run 2156
    
    5.5 Hours of 28 uA of Beam