User name apar
Log entry time 12:33:13 on June 19, 2004
Entry number 126309
keyword=Start_Parity_Run_2280__CODA_Config=happex2_Run_type=production,beam_energy=3.028,beam_polarization=86.0,beam_raster=on,comment_text=Production,leftarm_p=3.009,leftarm_theta=6,parity_feedback=on,parity_ihwp=out,rightarm_p=3.005,rightarm_theta=6,target_fanspeed=24,target_type=20cm LHe
Beginning-of-Parity-run EPICS data for Run Number 2280 at Sat Jun 19 12:32:11 EDT 2004
CODA Configuration: happex2
# Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 15.9458
Wien BDL : 369.04
Wien field : 10.527
Laser attenuation Hall A : 66
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 2250
IA Cell Setpoint Hall A : 4.95
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5
Gun2: PC (PITA) NEG : 5
Gun3: PC (PITA) POS : 3.688
Gun3: PC (PITA) NEG : 8.105
Pockels Cell Voltage POS : 2.58852
Pockels Cell Voltage NEG : 2.76679
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
LUMI HV - Ch 0 : -375.1
LUMI HV - Ch 1 : -600.6
LUMI HV - Ch 2 : -425.5
LUMI HV - Ch 3 : -374.9
LUMI HV - Ch 4 : -433.7
LUMI HV - Ch 5 : -350.4
LUMI HV - Ch 6 : -376
LUMI HV - Ch 7 : -375.6
LUMI HV - Ch 8 : -13.3
LUMI HV - Ch 9 : -18.6
LUMI HV - Ch 10 : -19
LUMI HV - Ch 11 : -13.1
HAPPEX Detector1 HV - Left Slot10 Ch9 : -1326.9
HAPPEX Detector2 HV - Left Slot10 Ch10 : -10.5
HAPPEX Detector3 HV - RightB Slot10 Ch10 : -1251.1
HAPPEX Detector4 HV - RightB Slot10 Ch9 : -10.7
Scanner Left HV - Left Slot10 Ch11 : -7.4
Scanner Right HV - RightB Slot10 Ch11 : -4.7
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left septum set current : 278.8
Left septum current readback : 278.25
Left septum upper coil T : 6.25
Left septum lower coil T : 7.65
Left septum yoke T : 4.85
Left septum bore shield T : 81.75
Left Arm Q1 power supply current : 1806.96
Left Arm Q1 momentum : 3.0091
Left Arm Q1 gauss meter : -0.15248
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1305.84
Left Arm Q2 momentum : 3.00919
Left Arm Q2 gauss meter : 0.6876
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1055.4
Left Arm D1 momentum : 3.00901
Left Arm D1 NMR : 1.11418
Left Arm Q3 power supply current : 1409.04
Left Arm Q3 momentum : 3.00892
Left Arm Q3 gauss meter : -0.7049
Left Arm Q3 power supply polarity : disabled
Right septum set current : 279.75
Right septum current readback : 278.25
Right septum upper coil T : 6.8
Right septum lower coil T : 6.6
Right septum yoke T : 5.75
Right septum bore shield T : 14.05
Right Arm Q1 power supply current : 1796.33
Right Arm Q1 momentum : 3.00486
Right Arm Q1 gauss meter : -0.04445
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1303.89
Right Arm Q2 momentum : 3.0047
Right Arm Q2 gauss meter : 0.6847
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1079.26
Right Arm D1 momentum : 3.00499
Right Arm D1 NMR : 1.11512
Right Arm Q3 power supply current : 1407.17
Right Arm Q3 momentum : 3.0049
Right Arm Q3 gauss meter : 0.6316
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 0.683594
Left Arm Bottom VDC Current : 0.732422
Right Arm Top VDC Current : -0.683594
Right Arm Bottom VDC Current : -0.732422
Left Arm Top VDC voltage : 0.0117188
Left Arm Bottom VDC voltage : 0.0112305
Right Arm Top VDC voltage : -0.00585938
Right Arm Bottom VDC voltage : -0.00439453
Average current of the two cavities : 7.65264
Current on Unser monitor : 2.76372
Current on Upstream bcm : 7.86747
Current on Downstream bcm : 7.43781
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 9.80442
Tiefenbach Hall A energy : 3041.32
Tiefenbach Hall C energy : 2037.85
Delta(E)/E width (MV_AI_DXWID) : 1.93781
MBSY1c Hall A Beam energy : 3033.17
MBSY3c Hall C Beam energy : 2042.63
MBSY1c magnet current (amp) : 126.281
MBSY1c Bdl : 756932
IPM1C12.XPOS : 4.94687
IPM1C12.YPOS : -4.7838
IPM1H04A.XPOS : 0.0508276
IPM1H04A.YPOS : -0.0892367
IPM1H04B.XPOS : -0.105335
IPM1H04B.YPOS : 0.0945411
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0577148
Left LVDT HPM : 3.441e+19
Left LVDT VPM : -127375
HacL_HPE1313A:0_Ch58 : -0.179688
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : 0.0351562
HacL_alignROLL : 0.374389
HacL_alignPITCH : -0.104089
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.321
Right Arm Collimator : -0.000292969
Right LVDT HPM : 3288
Right LVDT VPM : 3876
HacR_HPE1313A:0_Ch58 : -0.545898
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.889648
HacR_alignROLL : -0.410261
HacR_alignPITCH : -0.00944859
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Arc OTR x-position : 0.660411
Arc OTR y-position : 2.0866
Arc OTR x-width : 0.629421
Arc OTR y-width : 0.662522
Arc OTR data valid flag : No
Arc OTR In/Out : Sources adc bin bob crl doc lib pan tmp tst
fan frequency loop 1 : 47.5
fan frequency loop 2 : 0
fan frequency loop 3 : 0
Encoder position : 32960132
temperature loop 1-1 : 7.02
temperature loop 1-2 : 7.06
temperature loop 1-3 : 7.69
temperature loop 2-1 : 94.98
temperature loop 2-2 : 86.42
temperature loop 2-3 : 94.98
temperature loop 3-1 : 94.98
temperature loop 3-2 : 94.98
temperature loop 3-3 : 94.98
pressure loop D2 : 27.3463
pressure loop H2 : 32.8038
Parameters used for HAPPEX feedback
anatype fdbk
curmon bcm3
feedback IA on 2 bcm3
feedback PZT onc 20 bpm4b
IAparam slope -154.3