User name apar
Log entry time 16:38:04 on June 19, 2004
Entry number 126337
keyword=Start_Parity_Run_2286__CODA_Config=happex2_Run_type=production,beam_energy=3.028,beam_polarization=86.0,beam_raster=on,comment_text=Back to production, IHWP IN,leftarm_p=3.009,leftarm_theta=6,parity_feedback=on,parity_ihwp=in,rightarm_p=3.005,rightarm_theta=6,target_fanspeed=24,target_type=20cm LHe
Beginning-of-Parity-run EPICS data for Run Number 2286 at Sat Jun 19 16:37:12 EDT 2004
CODA Configuration: happex2
# Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 15.9458
Wien BDL : 369.04
Wien field : 10.527
Laser attenuation Hall A : 173
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 6500
IA Cell Setpoint Hall A : 3.32
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5
Gun2: PC (PITA) NEG : 5
Gun3: PC (PITA) POS : 3.939
Gun3: PC (PITA) NEG : 6.65
Pockels Cell Voltage POS : 2.60806
Pockels Cell Voltage NEG : 2.68132
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
LUMI HV - Ch 0 : -375.1
LUMI HV - Ch 1 : -600.6
LUMI HV - Ch 2 : -425.5
LUMI HV - Ch 3 : -374.9
LUMI HV - Ch 4 : -433.7
LUMI HV - Ch 5 : -350.4
LUMI HV - Ch 6 : -376
LUMI HV - Ch 7 : -375.6
LUMI HV - Ch 8 : -13.3
LUMI HV - Ch 9 : -18.6
LUMI HV - Ch 10 : -19
LUMI HV - Ch 11 : -13.1
HAPPEX Detector1 HV - Left Slot10 Ch9 : -1326.9
HAPPEX Detector2 HV - Left Slot10 Ch10 : -10.5
HAPPEX Detector3 HV - RightB Slot10 Ch10 : -1251.1
HAPPEX Detector4 HV - RightB Slot10 Ch9 : -10
Scanner Left HV - Left Slot10 Ch11 : -7.4
Scanner Right HV - RightB Slot10 Ch11 : -4.7
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left septum set current : 278.8
Left septum current readback : 278.25
Left septum upper coil T : 6.85
Left septum lower coil T : 7.65
Left septum yoke T : 5.2
Left septum bore shield T : 81.85
Left Arm Q1 power supply current : 1806.9
Left Arm Q1 momentum : 3.0091
Left Arm Q1 gauss meter : -0.15249
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1305.75
Left Arm Q2 momentum : 3.00899
Left Arm Q2 gauss meter : 0.6877
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1055.4
Left Arm D1 momentum : 3.00901
Left Arm D1 NMR : 1.11418
Left Arm Q3 power supply current : 1409.02
Left Arm Q3 momentum : 3.00887
Left Arm Q3 gauss meter : -0.7049
Left Arm Q3 power supply polarity : disabled
Right septum set current : 279.75
Right septum current readback : 278.25
Right septum upper coil T : 7.65
Right septum lower coil T : 7.55
Right septum yoke T : 6.2
Right septum bore shield T : 15.25
Right Arm Q1 power supply current : 1796.33
Right Arm Q1 momentum : 3.00486
Right Arm Q1 gauss meter : -0.04442
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1304.01
Right Arm Q2 momentum : 3.00498
Right Arm Q2 gauss meter : 0.6847
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1079.25
Right Arm D1 momentum : 3.00499
Right Arm D1 NMR : 1.11512
Right Arm Q3 power supply current : 1407.22
Right Arm Q3 momentum : 3.00503
Right Arm Q3 gauss meter : 0.6316
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 0.683594
Left Arm Bottom VDC Current : 0.683594
Right Arm Top VDC Current : -0.78125
Right Arm Bottom VDC Current : -0.732422
Left Arm Top VDC voltage : 0.0107422
Left Arm Bottom VDC voltage : 0.0117188
Right Arm Top VDC voltage : -0.00488281
Right Arm Bottom VDC voltage : -0.00537109
Average current of the two cavities : 28.2015
Current on Unser monitor : 23.9797
Current on Upstream bcm : 28.9683
Current on Downstream bcm : 27.4348
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 49.0678
Tiefenbach Hall A energy : 3028.01
Tiefenbach Hall C energy : 2037.81
Delta(E)/E width (MV_AI_DXWID) : 2.62635
MBSY1c Hall A Beam energy : 3033.17
MBSY3c Hall C Beam energy : 2042.63
MBSY1c magnet current (amp) : 126.281
MBSY1c Bdl : 756932
IPM1C12.XPOS : 0.0036453
IPM1C12.YPOS : 0.130126
IPM1H04A.XPOS : 0.142711
IPM1H04A.YPOS : -0.108816
IPM1H04B.XPOS : -0.119813
IPM1H04B.YPOS : 0.0848575
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0578125
Left LVDT HPM : 3.441e+19
Left LVDT VPM : -127373
HacL_HPE1313A:0_Ch58 : -0.179199
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : 0.0356445
HacL_alignROLL : 0.374002
HacL_alignPITCH : -0.1046
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.321
Right Arm Collimator : -0.000439453
Right LVDT HPM : 3288
Right LVDT VPM : 3875
HacR_HPE1313A:0_Ch58 : -0.545898
HacR_HPE1313A:0_Ch55 : 21.9727
HacR_HPE1313A:0_Ch54 : -0.890137
HacR_alignROLL : -0.41081
HacR_alignPITCH : -0.00938237
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Arc OTR x-position : 0.660411
Arc OTR y-position : 2.0866
Arc OTR x-width : 0.629421
Arc OTR y-width : 0.662522
Arc OTR data valid flag : No
Arc OTR In/Out : Sources adc bin bob crl doc lib pan tmp tst
fan frequency loop 1 : 48
fan frequency loop 2 : 0
fan frequency loop 3 : 0
Encoder position : 32960132
temperature loop 1-1 : 7
temperature loop 1-2 : 7.04
temperature loop 1-3 : 7.73
temperature loop 2-1 : 94.98
temperature loop 2-2 : 85.47
temperature loop 2-3 : 94.98
temperature loop 3-1 : 94.98
temperature loop 3-2 : 94.98
temperature loop 3-3 : 94.98
pressure loop D2 : 27.2049
pressure loop H2 : 32.5734
Parameters used for HAPPEX feedback
anatype fdbk
curmon bcm3
feedback IA on 2 bcm3
feedback PZT onc 20 bpm4b
IAparam slope -154.3