User name apar
Log entry time 00:17:20 on June 22, 2004
Entry number 126603
keyword=End_of_Parity_Run_2359__CODA_Config=happex2
************************************************
Run Number: 2359
End of Run Comment:
Run_type=production,beam_energy=3.028,beam_polarization=86.0,beam_raster=on,comment_text=30 uA, both arms in production,leftarm_p=3.009,leftarm_theta=6,parity_feedback=on,parity_ihwp=out,rightarm_p=3.005,rightarm_theta=6,target_fanspeed=48,target_type=20cm LHe
************************************************
End-of-Parity-run EPICS data for Run Number 2359 at Tue Jun 22 00:16:27 EDT 2004
CODA Configuration: happex2
# Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 15.9458
Wien BDL : 370.52
Wien field : 10.527
Laser attenuation Hall A : 110
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 2250
IA Cell Setpoint Hall A : 4.66
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5
Gun2: PC (PITA) NEG : 5
Gun3: PC (PITA) POS : 4.501
Gun3: PC (PITA) NEG : 7.262
Pockels Cell Voltage POS : 2.6398
Pockels Cell Voltage NEG : 2.72283
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
LUMI HV - Ch 0 : -375.1
LUMI HV - Ch 1 : -600.6
LUMI HV - Ch 2 : -425.5
LUMI HV - Ch 3 : -374.9
LUMI HV - Ch 4 : -433.7
LUMI HV - Ch 5 : -351.2
LUMI HV - Ch 6 : -376
LUMI HV - Ch 7 : -375.6
LUMI HV - Ch 8 : -13.3
LUMI HV - Ch 9 : -19.4
LUMI HV - Ch 10 : -19
LUMI HV - Ch 11 : -13.1
HAPPEX Detector1 HV - Left Slot10 Ch9 : -1326.9
HAPPEX Detector2 HV - Left Slot10 Ch10 : -10.5
HAPPEX Detector3 HV - RightB Slot10 Ch10 : -1251.1
HAPPEX Detector4 HV - RightB Slot10 Ch9 : -10
Scanner Left HV - Left Slot10 Ch11 : -8.1
Scanner Right HV - RightB Slot10 Ch11 : -4.7
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left septum set current : 278.57
Left septum current readback : 278.75
Left septum upper coil T : 6.4
Left septum lower coil T : 6.55
Left septum yoke T : 5.05
Left septum bore shield T : 82.75
Left Arm Q1 power supply current : 1806.85
Left Arm Q1 momentum : 3.00892
Left Arm Q1 gauss meter : -0.15246
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1305.69
Left Arm Q2 momentum : 3.00885
Left Arm Q2 gauss meter : 0.6876
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1055.41
Left Arm D1 momentum : 3.00901
Left Arm D1 NMR : 1.11418
Left Arm Q3 power supply current : 1409.11
Left Arm Q3 momentum : 3.00905
Left Arm Q3 gauss meter : -0.7048
Left Arm Q3 power supply polarity : disabled
Right septum set current : 279.75
Right septum current readback : 278.25
Right septum upper coil T : 7
Right septum lower coil T : 6.8
Right septum yoke T : 5.95
Right septum bore shield T : 13.25
Right Arm Q1 power supply current : 1796.33
Right Arm Q1 momentum : 3.00504
Right Arm Q1 gauss meter : -0.04443
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1304.15
Right Arm Q2 momentum : 3.00529
Right Arm Q2 gauss meter : 0.6847
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1079.96
Right Arm D1 momentum : 3.00499
Right Arm D1 NMR : 1.11512
Right Arm Q3 power supply current : 1407.36
Right Arm Q3 momentum : 3.00531
Right Arm Q3 gauss meter : 0.6316
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 0.585938
Left Arm Bottom VDC Current : 0.634766
Right Arm Top VDC Current : -0.732422
Right Arm Bottom VDC Current : -0.732422
Left Arm Top VDC voltage : 0.0102539
Left Arm Bottom VDC voltage : 0.0107422
Right Arm Top VDC voltage : -0.00585938
Right Arm Bottom VDC voltage : -0.00537109
Average current of the two cavities : 0.045251
Current on Unser monitor : -5.64673
Current on Upstream bcm : 0.032357
Current on Downstream bcm : 0.0581449
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.001435
Tiefenbach Hall A energy : 3028.47
Tiefenbach Hall C energy : 2038.06
Delta(E)/E width (MV_AI_DXWID) : 1.01824
MBSY1c Hall A Beam energy : 3033.17
MBSY3c Hall C Beam energy : 2042.63
MBSY1c magnet current (amp) : 126.281
MBSY1c Bdl : 756932
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0578613
Left LVDT HPM : 3.441e+19
Left LVDT VPM : -127374
HacL_HPE1313A:0_Ch58 : -0.180664
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : 0.034668
HacL_alignROLL : 0.373537
HacL_alignPITCH : -0.10329
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.321
Right Arm Collimator : -0.000390625
Right LVDT HPM : 3288
Right LVDT VPM : 3875
HacR_HPE1313A:0_Ch58 : -0.545898
HacR_HPE1313A:0_Ch55 : 22.0703
HacR_HPE1313A:0_Ch54 : -0.890625
HacR_alignROLL : -0.411247
HacR_alignPITCH : -0.00944859
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Arc OTR x-position : 0.660411
Arc OTR y-position : 2.0866
Arc OTR x-width : 0.629421
Arc OTR y-width : 0.662522
Arc OTR data valid flag : No
Arc OTR In/Out : Sources adc bin bob crl doc lib pan tmp tst
fan frequency loop 1 : 48
fan frequency loop 2 : 0
fan frequency loop 3 : 0
Encoder position : 32960132
temperature loop 1-1 : 7.01
temperature loop 1-2 : 7.05
temperature loop 1-3 : 7.6
temperature loop 2-1 : 94.98
temperature loop 2-2 : 87.22
temperature loop 2-3 : 94.98
temperature loop 3-1 : 94.98
temperature loop 3-2 : 94.98
temperature loop 3-3 : 94.98
pressure loop D2 : 27.3463
pressure loop H2 : 32.8649
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_2359.log:
Cumulative stats for 8088 events:
bcm1 raw insufficient data
bcm1 insufficient data
bcm2 raw insufficient data
bcm2 insufficient data
Events failing cut conditions:
0 Low_beam 8088
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 1
4 Startup 1